7. GARDEN EXAMPLE

Proposals for installation and settings

Area: 3000 m2. There are several islands. No guide wire is necessary. The mower’s default settings do not need to be changed.

Timer: Operating time of 15 hours per day.

Exit angles: 90°- 270°.

Search method: Irregular.

Delay: Guide 1 4 minutes, Guide 2 4 minutes and boundary wire 11 minutes.

Corridor width: 10

Area: 1000 m2. There is one small island. Guide wire recommended through the passage.

Timer: Operating time of 5 hours per day.

Exit angles: 70° - 190°.

Follow loop out: Direction Guide 1, Distance 20 m and Proportion 25 %.

Search method: Irregular, Follow guide wire in and Follow boundary wire in.

Delay: Guide 1 4 minutes, Guide 2 4 minutes and boundary wire 11 minutes.

Corridor width: Guide 1 7, boundary wire 20.

Area: 4000 m2. Two guide wires are recommended.

Timer: Operating time of 24 hours per day.

Exit angles: 90°-270°.

Follow loop out: Area 1; Direction Guide 1,

Distance 30 m and Proportion 15 %. Area 2;

Direction Guide 2, Distance 30 m and

Proportion 30 %.

Search method: Irregular, Follow guide wire in and Follow boundary wire in.

Delay: Guide 1 2 minutes, Guide 2 2 minutes and boundary wire 11 minutes.

Corridor width: Guide 1 4, Guide 2 4 and boundary wire 6.