hussman R3P-0608, IGFP-R3 manual User Information Contd, When cleaning

Models: IGFP-R3 R3 R3P R3P-0608 Refrigerated Service and/or Prep with Refrigerated Self Service Front

1 33
Download 33 pages 51.54 Kb
Page 15
Image 15

Rev. 0608

User Information (Cont'd)

Non-glare Glass

Windex® or Glass Plus® are the only solutions recommended to be used to clean the non-glare glass. The damage to the glass from improper, caustic solutions is irreparable.

In addition to cleaning the glass with the recommended product, there are precautions that should be taken when working and cleaning the inside of the case.

When cleaning the inside of the cases, we recommend that the glass be fully opened and covered to prevent to prevent solutions from splashing onto the glass and ruining the coating on the inside.

Plexiglass and Acrylic Care

Improper cleaning not only accelerates the cleaning cycle but also degrades the quality of this surface. Normal daily buffing motions can generated static cling attracting dust to the surface. Incorrect cleaning agents or cleaning cloths can cause micro scratching of the surface, causing the plastic to haze over time.

Cleaning

Hussmann recommends using a clean damp chamois, or a paper towel marketed as dust and abrasive free with 210® Plastic Cleaner and Polish available by calling Sumner Labs at 1-800-542-8656. Hard, rough cloths or paper towels will scratch the acrylic and should not be used.

Antistatic Coatings

The 210® has proven to be very effective in not only cleaning and polishing the Plexiglass surface, but also providing antistatic and anti-fog capabilities. This product also seals pores and provides a protective coating.

CLEANING PRECAUTIONS

When cleaning:

Do not use high pressure water hoses

Do not introduce water faster than waste outlet can drain

NEVER ON A SELF CONTAINED UNIT WITH AN EVAPORATOR FAN

NEVER USE A CLEANING OR SANITIZING SOLUTION THAT HAS AN OIL BASE (these will dissolve the butyl sealants) or an AMMONIA BASE (this will corrode the copper componets of the case)

TO PRESERVE THE ATTRACTIVE FINISH:

DO USE WATER AND A MILD DETERGENT FOR THE EXTERIOR ONLY

DO NOT USE ABRASIVES OR STEEL WOOL SCOURING PADS

(these will mar the finish)

Evaporator Fans

The evaporator fans are located at the center front of these merchandisers directly beneath the display pans. Should fans or blades need servicing, always replace fan blades with the raised embossed side of the blade TOWARD THE MOTOR.

Copper Coils

The copper coils used in Hussmann merchandisers may be repaired in the field. Materials are available from local refrigeration wholesalers.

Hussmann recommends using #15 Sil-Fos for repairs.

Tips and Troubleshooting

Before calling for service, check the following:

1.Check electrical power supply to the equipment for connection.

2.Check fixture loading. Overstocking case will affect its proper operation.

3.If frost is collecting on fixture and/or product, check that no outside doors or windows are open - allowing moisture to enter store. These merchandisers were designed for use in stores were temperature & humidity does not exceed 75° F and 55% H.

15

Page 15
Image 15
hussman R3P-0608, IGFP-R3 manual User Information Contd, When cleaning

IGFP-R3, R3, R3P, R3P-0608, Refrigerated Service and/or Prep with Refrigerated Self Service Front specifications

Hussmann Refrigerated Service and Prep Solutions offer innovative designs and advanced technologies that cater to the dynamic needs of the modern retail environment. Among their impressive line-up, the Refrigerated Self-Service Front models, particularly the R3P-0608 and its variants, stand out for their effective combination of functionality, energy efficiency, and user-friendly features.

The R3P series exemplifies Hussmann's commitment to providing high-quality refrigeration solutions that enhance customer experience. With a sleek design, these service fronts are not only appealing but also practical for various food service applications, including convenience stores and grocery operations. The self-service model allows customers easy access to a wide range of products, ensuring a seamless shopping experience whether it’s for pre-packaged meals, salads, or beverages.

One of the main features of the R3P series is its energy-efficient technology. Equipped with advanced refrigeration systems, these models operate effectively while maintaining optimal food temperatures. Hussmann integrates Eco-Design principles into the R3P, which help reduce its overall energy consumption without compromising performance. This is vital in today's retail environment, where operational costs continue to rise, and sustainability is a key customer concern.

The innovative design of the R3P also includes adjustable shelving and customizable display options, enabling retailers to optimize space for various product types. This flexibility allows businesses to display items clearly and attractively while maximizing visual appeal and accessibility. Additionally, the ergonomic design of the glass doors ensures easy access for both customers and staff, streamlining operations and improving product visibility.

The IGFP-R3 variant further exemplifies Hussmann's advanced technology with integrated features such as smart temperature controls and monitoring systems. This variant is designed to enhance food safety by ensuring that products are kept at the recommended temperatures, providing peace of mind to both retailers and consumers.

Overall, Hussmann Refrigerated Service and Prep solutions, particularly the R3P-0608 and related models, represent an ideal blend of style, efficiency, and functionality. The emphasis on energy savings, customization, and food safety makes these solutions integral to the success of modern food retail and service environments. As retailers continue to seek competitive edges, the R3P series by Hussmann remains a leading choice in refrigeration technology, offering exceptional value and innovation.