Annual Maintenance

Contact the Customer Service Representative in

your region using the contact information sheet

After a period of nonuse, we recommend that you

provided with your manual.

perform the following maintenance procedures for your

Check:

safety.

3)

Valves-to-manifold connections.

m WARNING: Check the hose before each use of

4)

The hose-to-regulator connection.

the barbecue for nicks, cracking, abrasions or

m WARNING: If there is a leak at connections (2),

cuts. If the hose is found to be damaged in any

(3) or (4), turn OFF the gas. DO NOT OPERATE

way, do not use the barbecue. Replace using only

THE BARBECUE. Contact the Customer Service

Weber authorized replacement hose. Contact the

Representative in your region using the contact

Customer Service Representative in your region

information sheet provided with your manual.

using the contact information sheet provided with

When leak checks are complete, turn gas supply OFF

your manual.

at the source and rinse connections with water.

Inspect the burners for correct flame pattern. Clean

 

 

if necessary, following the procedures outlined in the

 

 

“General Maintenance” section of this manual. Check all gas fittings for leaks.

m DANGER

 

Do not use an open flame to check for gas

 

leaks. Be sure there are no sparks or open

(1)

flames in the area while you check for

 

leaks. Sparks or flames will result in a fire

(2)

or explosion, which can cause serious

 

bodily injury or death, and damage to

 

property.

 

m WARNING: You should check for gas leaks every

 

time you disconnect and reconnect a gas fitting.

 

Note - All factory-made connections have been

 

thoroughly checked for gas leaks. The burners have

 

been flame tested. As a safety precaution however,

 

you should recheck all fittings for leaks before using

(3)

your Weber Gas Barbecue. Shipping and handling may

 

have loosened or damaged a gas fitting.

 

m WARNING: Perform these leak checks even if

 

your barbecue was dealer- or store-assembled.

 

You will need: a soap and water solution and a rag or

 

brush to apply it.

(4)

To perform leak checks: Make sure all Burners are in

 

the off position. Turn on gas supply.

 

mWARNING: Do not ignite burners while leak checking.

Check for leaks by wetting the connections with the

 

Inspection and Cleaning of the Weber

soap and water solution and watching for bubbles. If

 

 

 

Spider Stopper™ Guards

bubbles form, or if a bubble grows, there is a leak.

 

 

 

To inspect the Spider Stopper Guards, remove the

Note - Since some leak test solutions, including soap

 

 

and water, may be slightly corrosive, all connections

 

control panel and look to see if they have dust or dirt

 

 

should be rinsed with water after checking for leaks.

 

on their outside surfaces. If they are dirty, brush off the

 

 

 

 

 

outside surface of the Spider Stopper Guards with a

 

 

 

Check:

 

soft bristle brush (an old toothbrush for example).

 

 

Check that there are no gaps in the Spider Stopper

 

1)

Hose-to-manifold connection.

 

Guards’ seams or in the fit around the burners or

 

2)

Regulator-to-Cylinder connection.

 

valves. (See Section “General Maintenance.”)

mWARNING: If there is a leak at connection (1), retighten the fitting with a wrench and recheck for leaks with soap and water solution.

If a leak persists after retightening the fitting, turn OFF the gas. DO NOT OPERATE THE BARBECUE.

D-7

Page 24
Image 24
Weber Gold B manual Annual Maintenance, Inspection and Cleaning of the Weber, Spider Stopper Guards