9) Reinstall the Spider Stopper Guards. Slightly

Crossover® Ignition System Operations

rotate the Spider Stopper Guards so that the

If the Crossover Ignition System fails to ignite the Left

seams are in line with the Venturi fins(1). There

burner, light the Left burner with a match. If the Left

should be no gaps in the seams or in the fit around

burner lights with a match, then check the Crossover

the burners(2) and valves(3).

Ignition System.

 

Check that both the white(1) and black(2) ignition

 

wires are attached properly.

(1)

(3)

(1)

(2)

(2)

m CAUTION: If the Spider Stopper Guards do not

 

 

 

 

 

 

fit tightly, contact the Customer Service Represen-

 

Check that the Crossover Ignition button pushes the

 

tative in your region using the contact information

 

igniter (button) down, and returns to the up position.

 

sheet provided with your manual.

 

Check to see if the igniter is loose in the frame.

 

m WARNING: After reinstalling the gas lines, they

 

Tighten if necessary; See Step “Install igniter” for

 

should be leak checked with a soap and water

 

correct procedure.

 

solution before using the barbecue. (See Step:

 

If the Crossover Ignition System still fails to light,

“Check for gas leaks.”)

 

Contact the Customer Service Representative in your

 

 

 

region using the contact information sheet provided

 

 

 

 

with your manual.

 

 

D-10

Page 27
Image 27
Weber Gold B manual Crossover Ignition System Operations