APPENDIX A — INTERFACING XEROX PRINTERS

Page A-15

Auto PFS suppression: This option causes the 5250 ALLY automatically to suppress all PFSs except the INIT, CR, LF and FF PFSs at the beginning of an XDPM print job. The XDPM job is delimited by one of the job start commands: s+Pd, s+Qd, s+Md, or s+Nd. This setting is useful only for XDPM data streams.

Suppress PFSs: This option causes the 5250 ALLY to suppress all PFSs for the data streams received on the twinax address. This allows the data stream to format the page without conflicts from System formatting requests. This option is useful for XPPM data streams. If the twinax address is receiving XPPM data to be sent to a printer in XPPM mode, this option should be set.

Suppress PFSs except bold and underline: This option is identical to Suppress, except that the BOLD ON, BOLDOFF, BSBOLD1, BSBOLD2, UNDL ON and UNDLOFF PFSs are not suppressed.

Auto PFS suppression except bold and underline: This option is identical to Auto PFS suppression, except that the BOLD ON, BOLDOFF, BSBOLD1, BSBOLD2, UNDL ON and UNDLOFF PFSs are also not suppressed.

To program this option:

 

!AGILE!0601=00;

Do not suppress PFSs

!AGILE!0601=01; Auto PFS suppression (default)

!AGILE!0601=02;

Suppress PFSs

!AGILE!0601=03; Suppress PFSs except bold and underline !AGILE!0601=04; Auto PFS suppression except bold and underline

0602 — Form Feed Suppression

The Form Feed suppression option can be useful for either XDPM or XPPM mode data streams, although it is probably most useful for XDPM mode. This option specifies how the 5250 ALLY will suppress Form Feeds. When Form Feed suppression is active, the 5250 ALLY will not send the FF PFS to the printer.

Do not suppress Form Feeds: This option tell the 5250 ALLY not to suppress the FF PFS. This means that Form Feeds received for this twinax address will be sent to the printer normally.

Auto Form Feed suppression: This option tells the 5250 ALLY to suppress the FF PFS automatically after receiving an XDPM job start command. These commands are: s+Pd, s+Qd, s+Md and s+Nd. Form feed suppression will continue until the XDPM job end command is received: s+Xd. This setting is useful only for XDPM data streams.

Page 177
Image 177
I-Data 5250 ALLY manual Form Feed Suppression

5250 ALLY specifications

The I-Data 5250 ALLY is a sophisticated device that combines cutting-edge technology with user-friendly features to enhance data management and interaction in various environments. Designed for flexible use, the ALLY caters to industry needs ranging from logistics and retail to healthcare and fieldwork.

One of the standout features of the I-Data 5250 ALLY is its robust processing power, which ensures seamless multitasking capabilities. Equipped with a high-performance processor, the device can handle complex applications and large data sets efficiently. This processing speed is critical for businesses that require rapid data collection and analysis.

The device boasts an impressive display that optimizes user experience. The high-resolution screen provides clear visibility under various lighting conditions, making it suitable for outdoor use. Additionally, the touchscreen interface makes navigation intuitive and enhances operational efficiency, reducing training time for new users.

Connectivity is another significant aspect of the I-Data 5250 ALLY. It supports multiple communication options, including Wi-Fi, Bluetooth, and cellular connections. This versatility ensures that users can stay connected regardless of their location, facilitating real-time data sharing and collaborations.

In terms of durability, the I-Data 5250 ALLY is built to withstand harsh conditions. It features a rugged design that is resistant to drops, dust, and water, making it an ideal choice for industries that operate in challenging environments. This durability extends the device's lifespan and reduces the need for frequent replacements.

Security is a paramount concern in today’s data-driven world, and the I-Data 5250 ALLY addresses this with advanced security features. It includes customizable user authentication protocols and data encryption mechanisms to protect sensitive information from unauthorized access and breaches.

Battery life is another critical feature of the I-Data 5250 ALLY. The device is equipped with a long-lasting battery that provides extended use on a single charge. This allows users to operate the device throughout their shifts without worrying about recharging, further enhancing productivity.

In summary, the I-Data 5250 ALLY stands out with its powerful processing capabilities, high-resolution display, robust connectivity options, rugged durability, and advanced security features. These characteristics make it an ideal tool for data collection and management in various sectors, where efficiency and reliability are essential. The I-Data 5250 ALLY is a testament to modern technological advancements, catering to the evolving needs of businesses today.