Page 3-7CHAPTER 3  CHARACTER CODE TRANSLATION
where nn represents the number of the table to set to default values.
Power-On Reset
If the user has made translation table changes and would like the unit to
return to its previous configuration, the user can cancel any unsaved
changes and return the unit to its former power-on state with the following
command:
!AGILE!=POR;
Save Configuration
After making any translation table changes, unless the changes are to be
temporary, the user must save the configuration to the 5250 ALLY flash
memory with the following command:
!AGILE!=SAVE;
Downloading an Entire Translation Table
Downloading an entire translation table uses the following format. The
example changes User Table 2 (Table 05) to a pass-through table:
!AGILE!#05@00=
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F
10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F
20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F
30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F
40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F
50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F
60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F
70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F
80 81 82 83 84 85 86 87 88 89 8A 8B 8C 8D 8E 8F
90 91 92 93 94 95 96 97 98 99 9A 9B 9C 9D 9E 9F
A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 AA AB ACAD AE AF
B0 B1 B2 B3 B4 B5 B6 B7 B8 B9 BA BB BC BD BE BF
C0 C1 C2 C3 C4 C5 C6 C7 C8 C9 CA CB CCCD CE CF
D0 D1 D2 D3 D4 D5 D6 D7 D8 D9 DA DB DCDD DE DF
E0 E1 E2 E3 E4 E5 E6 E7 E8 E9 EA EB EC ED EE EF
F0 F1 F2 F3 F4 F5 F6 F7 F8 F9 FA FB FC FD FE FF
;