SSA RAID Adapter Installation and User's Guide.
|
| Appendix B. SSA RAID Adapter Service Request Numbers |
| |
¦ | 47500 ¦ Part of the RAID array data | ¦ Call for service | ¦ | |
¦ | ¦ might have been lost. | ¦ | ¦ | |
+ | ¦ | |||
¦ | 48000 ¦ The SSA adapter has detected | ¦ Go to "SSA Loop | ¦ | |
¦ | ¦ a loop configuration that is | ¦ Configurations that Are Not | ¦ | |
¦ | ¦ not valid. | ¦ Valid" in topic B.1 or call | ¦ | |
¦ | ¦ |
| ¦ for service | ¦ |
+ | ¦ | |||
¦ | 49000 ¦ A RAID array is in the | ¦ Call for service | ¦ | |
¦ | ¦ Degraded state because a disk ¦ | ¦ | ||
¦ | ¦ drive is not available to the ¦ | ¦ | ||
¦ | ¦ array, and a write command | ¦ | ¦ | |
¦ | ¦ has been sent to that array. | ¦ | ¦ | |
¦ | ¦ |
| ¦ | ¦ |
¦ | ¦ A disk drive might not be | ¦ | ¦ | |
¦ | ¦ available for one of the | ¦ | ¦ | |
¦ | ¦ following reasons: | ¦ | ¦ | |
¦ | ¦ |
| ¦ | ¦ |
¦ | ¦ | The disk drive has | ¦ | ¦ |
¦ | ¦ | failed. | ¦ | ¦ |
¦ | ¦ | The disk drive has been | ¦ | ¦ |
¦ | ¦ | removed from the | ¦ | ¦ |
¦ | ¦ | subsystem. | ¦ | ¦ |
¦ | ¦ | An SSA link has failed. | ¦ | ¦ |
¦ | ¦ | A power failure has | ¦ | ¦ |
¦ | ¦ | occurred. | ¦ | ¦ |
+ | ¦ | |||
¦ | 49100 ¦ A RAID array is in the | ¦ Call for service | ¦ | |
¦ | ¦ Exposed state because a disk | ¦ | ¦ | |
¦ | ¦ drive is not available to the ¦ | ¦ | ||
¦ | ¦ array. | ¦ | ¦ | |
¦ | ¦ |
| ¦ | ¦ |
¦ | ¦ A disk drive can become not | ¦ | ¦ | |
¦ | ¦ available for several | ¦ | ¦ | |
¦ | ¦ reasons: | ¦ | ¦ | |
¦ | ¦ |
| ¦ | ¦ |
¦ | ¦ | The disk drive has | ¦ | ¦ |
¦ | ¦ | failed. | ¦ | ¦ |
¦ | ¦ | The disk drive has been | ¦ | ¦ |
¦ | ¦ | removed from the | ¦ | ¦ |
¦ | ¦ | subsystem. | ¦ | ¦ |
¦ | ¦ | An SSA link has failed. | ¦ | ¦ |
¦ | ¦ | A power failure has | ¦ | ¦ |
¦ | ¦ | occurred. | ¦ | ¦ |
+ | ¦ | |||
¦ | 49500 ¦ No | ¦ Call for service | ¦ | |
¦ | ¦ available for a RAID array | ¦ | ¦ | |
¦ | ¦ that is configured for | ¦ | ¦ | |
¦ | ¦ | ¦ | ¦ | |
+ | ¦ | |||
¦ | 49700 ¦ The parity for the RAID array ¦ Call for service | ¦ | ||
¦ | ¦ is not complete. | ¦ | ¦ | |
+ | ¦ | |||
¦ | 50000 ¦ The SSA adapter failed to | ¦ Exchange the adapter card | ¦ | |
¦ | ¦ respond to the device driver. ¦ for a new one or call for | ¦ | ||
¦ | ¦ |
| ¦ service | ¦ |
+ | ¦ | |||
¦ | 50001 ¦ A data parity error has | ¦ Exchange the adapter card | ¦ | |
¦ | ¦ occurred. | ¦ for a new one or call for | ¦ | |
¦ | ¦ |
| ¦ service | ¦ |
+ | ¦ | |||
¦ | 50002 ¦ An SSA adapter DMA error has | ¦ Exchange the adapter card | ¦ | |
¦ | ¦ occurred. | ¦ for a new one or call for | ¦ | |
¦ | ¦ |
| ¦ service | ¦ |
+ | ¦ | |||
¦ | 50004 ¦ Channel check. | ¦ Exchange the adapter card | ¦ | |
¦ | ¦ |
| ¦ for a new one or call for | ¦ |
¦ | ¦ |
| ¦ service | ¦ |
+ | ¦ | |||
¦ | 50005 ¦ A software error has | ¦ Call for service | ¦ | |
¦ | ¦ occurred. | ¦ | ¦ | |
+ | ¦ | |||
¦ | 50006 ¦ A channel check has occurred. ¦ Exchange the adapter card | ¦ | ||
¦ | ¦ |
| ¦ for a new one or call for | ¦ |
_ Copyright IBM Corp. 1996
B.0 - 3