v
The
connector
processes
the
first
BO
attachment.
The
data
handler
is
available
for
this
MIME
type,
so
it
sends
the
business
object
to
Visual
Test
Connector.
v
When
it
is
polled
for
the
second
time,
the
connector
processes
the
second
BO
attachment.
The
data
handler
is
available
for
this
MIME
type,
so
it
sends
the
business
object
to
Visual
Test
Connector.
v
Once
it
is
accepted,
the
third
BO
attachment
should
be
transmitted.
PollStartTime
The
PollStartTime
property
specifies
the
time
to
start
polling
the
event
queue.
The
format
is
HH:MM,
where
HH
is
0
through
23
hours,
and
MM
represents
0
through
59
minutes.
You
must
provide
a
valid
value
for
this
property.
The
default
value
is
HH:MM
without
a
value,
and
it
must
be
changed.
If
the
adapter
runtime
detects:
v
PollStartTime
set
and
PollEndTime
not
set,
or
v
PollEndTime
set
and
PollStartTime
not
set
it
will
poll
using
the
value
configured
for
the
PollFrequency
property.
RepositoryDirectory
The
RepositoryDirectory
property
is
the
location
of
the
repository
from
which
the
connector
reads
the
XML
schema
documents
that
store
the
metadata
for
business
object
definitions.
If
the
integration
broker
is
ICS,
this
value
must
be
set
to
set
to
<REMOTE>
because
the
connector
obtains
this
information
from
the
InterChange
Server
repository.
When
the
integration
broker
is
a
WebSphere
message
broker
or
WAS,
this
value
is
set
to
<ProductDir>\repository
by
default.
However,
it
may
be
set
to
any
valid
directory
name.
RequestQueue
The
RequestQueue
property
specifies
the
queue
that
is
used
by
the
integration
broker
to
send
business
objects
to
the
connector.
This
property
is
valid
only
if
the
value
of
the
DeliveryTransport
property
is
JMS.
The
default
value
is
<CONNECTORNAME>/REQUESTQUEUE.
ResponseQueue
The
ResponseQueue
property
specifies
the
JMS
response
queue,
which
delivers
a
response
message
from
the
connector
framework
to
the
integration
broker.
When
the
integration
broker
is
ICS,
the
server
sends
the
request
and
waits
for
a
response
message
in
the
JMS
response
queue.
This
property
is
valid
only
if
the
value
of
the
DeliveryTransport
property
is
JMS.
The
default
value
is
<CONNECTORNAME>/RESPONSEQUEUE.
Appendix
A.
Standard
configuration
properties
for
connectors
103