This window is used to define Warning and Critical thresholds unique to a pa rticular storage subsystem, 
overriding the values defined in the disk storage class. The user may modify either the Warning percent,  
Critical percent or both for one or more of the listed subsystems. Select a subsystem from the  list and 
then modify the values on the lower portion of the window. When the new values have been entered, 
select Update to commit the changes. To remove the overridden threshold values, select the Set To 
Defaults button. The changes will be committed and displayed in the Subsystem Thresholds  table. 
After any modifications to the subsystem-specific thresholds, the Core Server and Migration Purge 
Server for those subsystems must be recycled to make the changes effective.
Field Descriptions
Storage Class ID. The ID of the storage class to which these subsystem-specific thresholds apply.
Storage Class Type. The type of storage class (disk or tape).
Storage Class Name. The Descriptive Name of the storage class.
Default Warning Threshold. The default warning threshold for this storage class  expressed as a 
percentage of used space.
Default Critical Threshold. The default critical threshold for  this storage class expressed as a 
percentage of used space.
Storage Subsystem Count. The number of storage subsystems in the HPSS system.
Subsystem List. A list of configured storage subsystems.  Columns in the list include:
Subsys ID. The ID of the selected storage subsystem.
HPSS Management Guide November 2009
Release 7.3 (Revision 1.0) 167