Fill Count. The number of cartridge labels to be added to the end of the li st when the Volume Label
field is next modified. This number may be one or greater. If the list fills up before the Fi ll Count is
exhausted, filling stops, and a message box is displayed (see Maximum Volumes Allowed below).
Fill Increment. In a multiple-cartridge fill, this field determines how each new cartr idge label is
generated from the previous one. A cartridge label is six alphanumeric characters. The Fill Increment is
added to the least significant part of a cartridge label to generate a new l abel.
Volume Label. The cartridge label to be added to the end of the Volume List. If Fill Count is greater
than 1, this will be the first label of a fill sequence. The label must be exactly six characters long.
Maximum Volumes Allowed. The maximum number of cartridge labels that will be allowed i n the
Volume List (10,000).
Total Count. The total number of labels currently in the Volume List.
Volume List. A list of cartridge/volume labels specifying the cartridges to be moved. You cannot enter
labels directly into this list, but must construct it in one of the t hree ways described above. Use the
scrollbar to move up and down the list of labels.
You can select one or more labels from the list for the purpose of removing them from the list (see Clear
Selected below).
Buttons
Clear All. Clears the Volume List, and resets Fill Count and Fill Incr ement to 1.
Clear Selected. If one or more cartridges are selected (highlighted) in the Volume List, cl icking on this
button will remove them from the list. Note that this does not actually delete anything from HPSS.
Move Cartridges. Begins moving the listed cartridges. A start message is displayed on the message line
at the bottom of the window, and all window features are disabled, except for the Dismiss button; this
prevents you from modifying any data on the window while the move is in progress.
It is a good idea to have the HPSS Alarms and Events window open while moving proceeds, so that all
relevant log messages can be viewed. Move operation initiation, completion and errors will be r eported
in the HPSS Alarms and Events window.
While moving proceeds, status messages are displayed on the status bar. When the move is finished, a
completion message is displayed and the window features are reenabled. At this point new data can be
entered for a new move.
8.6. Monitoring and Mana ging Volume Mounts
Volume mounts are performed by the PVL. Every volume mount is associated with a PVL job. The PVL
Job Queue window, lists all PVL jobs and the PVL Request Information window lis ts detailed
information about a single PVL job.
The PVL reports every tape mount request in the Tape Mount Requests window. Tapes which need to be
returned to the robot from a shelf or vault location are reported in the Tape Check-In Requests window.
Each of these windows is described in detail in this section.
HPSS Management Guide November 2009
Release 7.3 (Revision 1.0) 283