
Mount Option  Mount Description
acdirtimeo Seconds to cache directory attributes.  The shorter this value, the more frequentl y 
communication to HPSS is required.  Synchronization between separate vfs nodes 
or mount points may benefit for a shorter cache period with the expense of longer 
latencies. 
flushd The flush deamons look for data pages that need to be written to HPSS, either tim e 
to write or data pages being requested for other files. Each daemon consumes 
resources so care should be taken when changing this option.  Another possibili ty is 
to change iomax to allow more pages to be available. 
rtimeo / wtimeo Performance gains can be realized when minimizing the number of transf ers.  This 
timeout allows multiple requests to be combined within the time limit. 
rpages / wpages Each specifies the maximum number of kernel buffer pages  that can be dedicated to 
individual file transfers.  Care must be taken to configure this correctly to the  
expected number of concurrent transfers and the iomax mount option. 
iomax Maximum number of kernel buffer pages (4096 bytes + overhead) that can be 
allocated for data buffers when transferring file data.  Each mount point has  its own 
set of data buffers.  Since these pages consume RAM resources, this must be 
compatible with application loads and transfer goals for the system.   For instan ce, 
the more pages allocated to the mount point, the less RAM available for 
applications.  This should also be consistent with rpages and wpages. 
fcsize File Cache Size.  Cache this much of the file on first access.  This con sumes 
resources so care must be taken not to make this too large.  Configuring  this to 
typical file access patterns will speed access when large enough to cache f uture 
requests. 
san / nosan Configures the mount point to transfer data from buffers directly to  SAN devices. 
shm Shared Memory (need to look into this)
dio Configures the mount point to transfer data to/from directly from application  space.  
This bypasses Linux VFS file buffering, see ???? for a discussion on advantages 
that the Linux VFS buffering provides. 
trace Level of messages logged from the HPSS kernel extension to /var/log/messages.  
Ranges from 0 to 5 with 0 being the least and 5 being lots. 
sharefd / nosharefd 
rattr Typically short directory listings do not have to access HPSS for file attributes.  
Specifying this option will force all directory listings to retrieve file attributes  from 
HPSS.  If the application is always doing long directory listings this has no effect .  If 
the application always requests short directory listings, this will delay those requests  
needlessly. 
ip Configure the network interfaces to use. 
cos Specify the default Class Of Service to use.  This can be overridden by an ioctl() 
system call once the file is created but BEFORE any data is written.  Standard Linux 
commands / library functions will not use the ioctl(), they will use the COS setting  for 
files stored in a fileset. 
ro / rw File system will be ro=read only or rw=read write. 
maxsegsz Use the maximum segment size for the storage class.  If not used, the m inimum 
segment size is used.  An application can use ioctl() to set this per  file once the file is 
created but BEFORE any data is written. 
HPSS Management Guide November 2009
Release 7.3 (Revision 1.0) 353