Multi–Platform Interface Feature Operation Guide 61
6400-LU1-SCS-Remote SNA 3174 Control Unit
LU1-SCS mode is utilized when neither
IPDS nor PSF is needed to accomplish the
print function desired. An existing remote
3174 SNA-connected control unit is
assumed. The steps required to install a
remote LU1-SCS printer for host definitions
are as follows:
1. Define to NCP, point to LU1 Logmode
entry defined below
2. Define to VTAM by adding logmode
entry to VTAM Logmode Table
3. Define to JES2 (May not be required if
VPS. See details below)
4. Define to JES328X Print Facility, VPS,
or equivalent product.
5. Select the options on the printer that
are appropriate for the environment.
Step 1 – NCP Definition
XYZ GROUP TYPE=NCP,...
LINK ADDRESS=(032),...
REMPU74 PU ADDR=C1,...
REM64XX LU LOCADDR=#, (# replaced by port on control
unit)
DLOGMOD=64XXSCSR,(Default LOGMODE ENTRY NAME)
MODETAB=MYTABLE (Table name containing MODEENT)
*
Step 2 – VTAM Definition
*The following entry should be placed in
the VTAM MODE TABLE specified above
or another of your choice.
64XXSCSR MODEENT LOGMODE=64XXSCSR,
FMPROF=X'03',TSPROF=X'03',PRIPROT=X'B1'
SECPROT=X'90',COMPROT=X'3080',RUSIZES=X'87C6',
PSERVIC=X'01000000E100000000000000',
PSNDPAC=X'01',SRCVPAC=X'01'