PROBLEM | POSSIBLE CAUSE | PROBABLE FIX | |
Does not vend | No ice | Check ice machine | |
| No power | Check power supply | |
|
|
| |
| Vend switch open | Check / replace vend switch | |
| Sink interlock switch open | Check / replace sink interlock | |
|
| switch | |
| Ice jams in chute | Machine is not level | |
|
|
| |
| Front panel not on all the way | Reinstall panel | |
| Gear motor open | Check/replace gearmotor | |
| Relay does not operate | Check wiring | |
|
| Check power to relay | |
|
| Check for burnt contacts | |
| Ice door does not open | Check for power to solenoid | |
|
| ||
|
| Check for disengaged door | |
|
| linkage | |
|
|
| |
| Drive shaft broken | Check/replace drive shaft | |
Coin Mechanism | Does not vend, no ice | Check the above, plus | |
coin switch | |||
|
| ||
|
| Check wiring | |
|
| Check timer | |
Leaks water | Bin drain leaks | Check bin drain connections | |
|
| and fittings | |
|
| Check for clogged bin drain | |
|
| tubing |