CD10022 | CD20030 |
CD10522 | CD20530 |
Removal and Replacement |
|
Electrical shock hazard. Electrical shock can cause personal injury. Disconnect power before begining to service components.
Gear Motor:
1.Disconnect electrical power.
2.Locate key and remove front panel.
3.Remove dispenser wheel.
4.Disconnect wires at gearmotor.
5.Remove 4 bolts securing gearmotor bracket to cabinet.
6.Pull gearmotor out of cabinet.
7.Remove gearmotor from bracket.
8.Reverse steps to reassemble.
Dispense Wheel:
1.Remove all of the ice stored inside the dispenser bin and shut off the ice maker.
2.Disconnect the electrical power.
3.Remove ice machine from dispenser.
4.Remove large dispenser top panel.
5.Reach into opening, locate the sweep arm which secures the wheel to the drive shaft. Remove the sweep arm.
6.Pull the wheel off the drive shaft and remove it from the dispenser.
7.Revese steps to reassemble.
16