Component Description

MFI Series

Component Description

●Control Box: Contains the electrical controls that operate the machine.

●High Pressure Cut Out Switch: An auto-reset switch sensing the high side refrigeration pressure. It will shut the machine off if the discharge pressure exceeds 450 psig.

●Low Pressure Cut Out Switch: An auto-reset switch sensing the low side refrigeration pressure. It will disconnect power to the circuit board and shut down the machine if the low pressure falls too low.

●Evaporator: A vertical stainless steel tube, refrigerated and water filled. Utilizes a stainless steel auger.

●Compressor: The refrigerant vapor pump.

●Water Reservoir: Float operated, it maintains the water level in the evaporator at a constant level, and it also contains the water level sensor.

●Water Level Sensor: Senses if there is water in the reservoir to make ice out of. Will shut the ice machine off if there is no water in the reservoir.

●Ice Discharge Chute: Directs the ice produced by the evaporator into the storage bin.

●Ice Level Sensor: An “electronic eye”, it senses the presence of ice in the bottom of the discharge chute.

●Gear Motor: An oil filled, speed reduction gearbox, driving the auger.

●Drain Tube: When uncapped and lowered, drains the evaporator.

●Condenser: Air or water cooled, where the heat removed in ice making is discharged.

●Expansion Valve: The refrigerant metering device.

Air Cooled Model Shown

Control Box

Condenser

Expansion Valve

 

Water Reservoir

 

 

High

 

Pressure

 

Cut Out

Drain Tube

 

 

 

Compressor

Gear Motor

Ice Discharge Chute

Ice Level Sensor

Page 10

Page 16
Image 16
Ice-O-Matic installation manual Component Description, Air Cooled Model Shown, MFI Series, Page