Ice-O-Matic MFI Operation Performance, Typical Low Side Pressure, Typical Discharge Pressure

Models: MFI

1 42
Download 42 pages 37.74 Kb
Page 21
Image 21

MFI Series

Operation: Performance

Beginning at the compressor, the refrigerant is compressed into a high temperature gas. The discharge line directs this gas to the condenser. At the condenser (air or water cooled) the gas is cooled by either air or water and then it condenses into a liquid.

This high pressure liquid then goes through the liquid line to the expansion valve. The thermostatic expansion valve meters liquid refrigerant into the evaporator, the volume of liquid refrigerant depending upon the temperature of the evaporator.

At the evaporator, the refrigerant enters an area of relatively low pressure, where it can easily “boil off” or evaporate. As it evaporates, it absorbs heat from the evaporator and whatever is in contact with it (such as water inside it). After the evaporator, the refrigerant, now a low pressure vapor, goes through the suction line back to the compressor, where the cycle is repeated.

Typical Low Side Pressure:

 

Air Cooled:

34-38 PSIG

Typical Discharge Pressure:

 

Air Cooled:

220-275 PSIG

Typical Compressor Amp Draw:

 

MFI0500AS 115/60/1

8-9 Amps

MFI0500WS 115/60/1

8-9 Amps

MFI0800AS 115/60/1

8-9 Amps

MFI0806AS 208-230/60/1

5-6 Amps

MFI0806WS 208-230/60/1

5-6 Amps

MFI0805AS 230/50/1

5-6 Amps

MFI1256AS 208-230/60/1

5-6 Amps

MFI1255AS 230/50/1

5-6 Amps

Typical Auger Drive Motor Amp Draw:

 

MFI0500AS 115/60/1

4.0 to 4.5 Amps

MFI0500WAS 115/60/1

4.0 to 4.5 Amps

MFI0800AS 115/60/1

4.0 to 4.5 Amps

MFI0806AS 208-230/60/1

1.6 to 3.8 Amps

MFI0806WS 208-230/60/1

1.6 to 3.8 Amps

MFI0805AS 230/50/1

1.6 to 3.8 Amps

MFI1256AS 208-230/60/1

1.6 to 3.8 Amps

MFI1255AS 230/50/1

1.6 to 3.8 Amps

Expansion Valve Superheat:

6-8 degrees

High Pressure Cut Out- Automatic Reset:

450 PSIG

Low Pressure Cut Out- Automatic Reset:

15 PSIG

Refrigerant Charge: R404A

 

MFI0500 Air Cooled

22 Ounces

MFI0500 Water Cooled

18 Ounces

MFI0800 Air Cooled

24 Ounces

MFI0806 Air Cooled

24 Ounces

MFI0806 Water Cooled

20 Ounces

MFI0805 Air Cooled

24 Ounces

MFI1256 Air Cooled

36 Ounces

MFI1255 Air Cooled

36 Ounces

 

Page 15

Page 21
Image 21