Ice-O-Matic Maintenance Air Cooled, Clean the air cooled condenser, MFI Series, Page

Models: MFI

1 42
Download 42 pages 37.74 Kb
Page 25
Image 25
Maintenance: Air Cooled

MFI Series

Maintenance: Air Cooled

Clean the air cooled condenser:

Air flow on this model is from front to back, so the inside of the ice machine will have to be available to clean the air cooled condenser. Use a vacuum cleaner or coil cleaner if needed. DO NOT use a wire brush.

Disconnect electrical power, and remove the air filter if applicable. The filter may be cleaned or replaced.

Clean the condenser: the condenser may appear to be clean on the surface, but it can still be clogged internally. Check with a flashlight from the front to see if light can be seen through the condenser fins.

Step 1. Remove the Top Panel Step 2. Remove two screws and

unplug fan motors.

Step 3. Pull fan motor assembly up and to the right to remove.

Step 4. Clean the condenser.

Step 1. Remove the Top Panel Step 2. Remove the top portion

of the fan shroud. Step 3. Clean the condenser.

Page 19

Page 25
Image 25
Ice-O-Matic installation manual Maintenance Air Cooled, Clean the air cooled condenser, MFI Series, Page