For the Plumber

MFI Series

For the Plumber

Water Inlet:

●Air Cooled Models: The recommended water supply is clean, cold water. Use 3/8 inch O.D. copper tubing, connect to the 3/8 inch male flare at the back of the cabinet. Install a hand valve near the machine to control the water supply.

●Water Cooled Models: A separate 3/8 inch O.D. copper line is recommended, with a separate hand valve to control it. Connect to the 3/8 inch FPT condenser inlet at the back of the cabinet. The water pressure to all lines must always be above 20 psig, and below 80 psig.

●Water Treatment: In most areas, a water filter of some type will be useful. In areas where the water is highly concentrated with minerals, the water should be tested by a water treatment specialist, and the recommendations of the specialist regarding filtration and/or treatment should be followed.

Drains:

●Air Cooled Models: Connect a rigid drain tube to the ¾ FPT drain fitting at the back of the cabinet. The drain is a gravity type, and a ¼ inch per foot fall is the minimum acceptable pitch for the drain. There should be a vent at the highest point of the drain line, and the ideal drain receptacle would be a trapped and vented floor drain. Use only ¾ inch rigid tubing.

●Water Cooled Models: Connect a separate drain line to the ½ inch condenser drain connection at the back of the cabinet. Do not vent this drain.

●Storage Bin: Connect a separate gravity type drain line to the ice storage bin drain. Vent this drain if there is a long horizontal run from the bin to the floor drain. Insulation of this drain line is recommended.

WATER COOLED MODELS

 

 

 

 

 

 

 

 

 

AIR COOLED MODELS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Condenser Inlet

 

 

 

 

 

 

 

 

 

 

 

Water Filter

 

 

 

 

 

 

 

 

 

 

 

Water Filter

 

 

 

Vented Drain

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vented Drain

Hand Valve

Hand Valve

Condenser Drain

Water In

Vented Drain

 

Vented Drain

 

 

 

Condenser Inlet

Water InletWater Inlet:

Water In

Condenser Drain WATER COOLED MODELS

Bin Drain

Bin Drain

Floor Drain