5-2 ADJUSTMENT

 

 

 

 

MEASUREMENT

 

ADJUSTMENT

ADJUSTMENT

ADJUSTMENT CONDITION

VALUE

POINT

 

 

 

 

 

 

UNIT

LOCATION

 

UNIT

ADJUST

 

 

 

 

 

 

 

 

REFERENCE

1

• Operating channel : Ch 35

Top

Loosely couple a fre-

433.925000 MHz

RF

C63

FREQUENCY

 

• Transmitting

 

panel

quency counter to the

 

 

 

 

 

 

 

 

antenna.

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

1

• Operating channel : Ch 35

RF

Connect an RF power

9 mW [ITA/–1]

RF

R206

POWER

 

• Transmitting

 

 

meter to the RF test

470 mW [CSA/–1]

 

 

 

 

 

 

 

port J1.

 

 

 

 

 

 

 

 

 

 

 

FM

1

• Operating channel : Ch 01

RF

Connect an FM devia-

±4.8 kHz

RF

R50

DEVIATION

 

• Connect an audio generator to the

 

tion meter to the RF

 

 

 

 

 

[MIC] jack and set as:

 

test port J1.

 

 

 

 

 

1 kHz/100 mV rms

 

 

 

 

 

 

 

• Set an FM deviation meter as:

 

 

 

 

 

 

 

HPF

: OFF

 

 

 

 

 

 

 

LPF

: 20 kHz or 15 kHz

 

 

 

 

 

 

 

De-emphasis

: OFF

 

 

 

 

 

 

 

Detector

: (P–P)/2

 

 

 

 

 

 

 

• Set group No.

: 01

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

• Set group No.

: OFF (– –)

 

 

10 mV ±3 dB

 

Verify

 

 

• Set an audio generator output level

 

 

 

 

 

 

 

until the deviation is ±3.5 kHz.

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SQUELCH

1

• Operating channel : Ch 35

Front

Internal speaker

 

Front

Push

 

 

• Connect an SSG to J1 on the RF unit

panel

 

 

panel

and hold

 

 

and set as:

 

 

 

 

 

[MODE]

 

 

Level

: 0.14 µV*

 

 

 

 

and

 

 

 

(–124 dBm)

 

 

 

 

[DOWN]

 

 

Modulation

: OFF

 

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

• Set an SSG as

:

 

 

Audio signal

 

Verify

 

 

Level

: OFF

 

 

disappears.

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 - 2

Page 12
Image 12
Icom IC-4008MKII service manual Adjustment, Deviation