REQUIRED TEST EQUIPMENT

EQUIPMENT

GRADE AND RANGE

EQUIPMENT

GRADE AND RANGE

 

 

 

 

 

 

DC power supply

Output voltage

: 13.2 V DC

Audio generator

Frequency range

: 300–3000 Hz

Current capacity

: 15 A or more

Measuring range

: 1–500 mV

 

 

 

 

 

 

 

 

 

Measuring range

: 1–100 W

Standard signal

Frequency range

: 0.1–600 MHz

RF power meter

Frequency range

: 300–600 MHz

Output level

: 0.1 µV–32 mV

generator (SSG)

(terminated type)

Impedance

: 50

 

(–127 to –17 dBm)

 

 

 

SWR

: Less than 1.2 : 1

 

 

 

 

Oscilloscope

Frequency range

: DC–20 MHz

 

 

 

 

 

 

 

Frequency range

: 0.1–600 MHz

Measuring range

: 0.01–20 V

 

 

Frequency counter

Frequency accuracy : ±1 ppm or better

 

 

 

AC millivoltmeter

Measuring range

: 10 mV–10 V

 

Sensitivity

: 100 mV or better

 

 

 

 

 

 

 

 

Input impedance

: 4

FM deviation meter

Frequency range

: DC–600 MHz

External speaker

Capacity

: 7 W or more

Measuring range

: 0 to ±10 kHz

 

 

 

 

 

 

 

 

Attenuator

Power attenuation

: 40 or 50 dB

Digtal multimeter

Input impedance

: 50 k/V DC or better

Capacity

: 100 W or more

 

 

 

 

 

 

 

 

 

 

Connections

Standard signal generator

–127 to –17 dBm

(0.1 V to 32 mV)

CAUTION:

DO NOT transmit while the SSG is connected to the antenna connector.

Personal computer

to an RS-232C port

FM deviation meter

 

RF power meter

(DC measurable)

 

50 / 1–100 W

 

 

 

 

 

 

Attenuator

 

 

40 dB or 50 dB

 

 

 

 

 

to the antenna connector

Frequency

counter

DC power supply to DC cable 13.2 V / 15 A

DB9 female plug

to the MIC connector

RS-232C cable

 

(straight)

*OPC-1122

 

(JIG CABLE)

Audio generator

AC millivoltmeter

5 - 2

Page 50
Image 50
Icom IC F121S, IC F110S, IC F111S service manual FM deviation meter RF power meter