SOFTWARE ADJUSTMENT – continued

Select an operation using [] / [] keys, then set specified value using [] / [] keys on the connected computer keyboard.

ADJUSTMENT

 

ADJUSTMENT CONDITION

 

 

MEASUREMENT

VALUE

 

 

 

 

 

 

UNIT

LOCATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RX

 

1

• Operating freq. :

136.000 MHz

 

MAIN

Connect a SINAD meter with a

Minimum distortion

SENSITIVITY

 

 

• IF bandwidth

: Wide

 

 

4 load to the external [SP]

level

 

[BPF T1],

 

 

• Connect a standard signal generator to

 

jack.

 

 

[BPF T2]

 

 

the antenna connector and set as:

 

 

 

 

 

 

 

Frequency

:

136.000 MHz

 

 

 

 

 

 

 

 

Level

:

10 µV* (–87 dBm)

 

 

 

 

 

 

 

Modulation

:

1 kHz

 

 

 

 

 

 

 

 

Deviation

: ±3.5 kHz

[N/W]

 

 

 

 

 

 

 

 

 

±2.8 kHz

[N/M]

 

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONVENIENT:

 

 

 

 

 

 

 

 

 

The BPF T1–BPF T2 can be adjusted automatically.

 

 

 

 

 

q-1: Set the cursol to “BPF ALL” on the adjustment program and then push [ENTER] key.

 

 

 

 

q-2: The connected PC tunes BPF T1, BPF T2 to peak levels.

 

 

 

 

 

 

or

 

 

 

 

 

 

 

 

w-1: Set the cursol to BPF T1 or BPF T2 as desired.

 

 

 

 

 

w-2: Push [ENTER] key to start tuning.

 

 

 

 

 

 

w-3: Repeat w-1 and w-2 to perform additional BPF tuning.

 

 

 

 

 

 

 

 

 

 

SQUELCH

 

1

• Operating freq. :

155.000 MHz

 

Rear

Connect a SINAD meter with a

Set “SQL level” to

LEVEL

 

 

• IF bandwidth

: Narrow

 

panel

4 load to the external [SP]

close squelch.

[SQL]

 

 

• Connect an SSG to the antenna con-

 

jack.

Then set “SQL level”

 

 

 

nector and set as:

 

 

 

 

 

 

 

 

 

at the point

where

 

 

 

Frequency

:

155.000 MHz

 

 

 

 

 

 

 

 

 

the audio

signals

 

 

 

Level

:

0.2 µV* (–121 dBm)

 

 

 

 

 

 

 

just appears.

 

 

 

Modulation

:

1 kHz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Deviation

: ±1.75 kHz

 

 

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.