ICP DAS USA MSM-508FCS, MSM-508FT user manual Relay Alarm, Relay Output

Models: MSM-508 MSM-508FCS MSM-508FC MSM-508FT

1 27
Download 27 pages 39.17 Kb
Page 17
Image 17

Industrial Ethernet Layer 2 Managed Switch – Web Management Manual

5.Relay Alarm

Managed Switch offer a relay contact output on Terminal Block of the Switch equipment. It is able to connect to a light, buzzer …etc. warning device and notify system failures immediately.

We also offer the web tool to configure the relay manually. It’s convenient for you to enable/disable relay warnings since the Switch equipments are far from you.

￿Relay Output

This function enables you to configure the relay warnings of Power, Link Lose and Communication Lose.

System Relay Alarm

When alarm occurred, the relay output on the Terminal Block is activated, and System Relay Alarm is turned ON.

Power Relay Enable

Managed Switch support dual power inputs to implement the power redundancy, and also support two relay configurations for those two power inputs.

You can tick the “Power1” or “Power2” checkbox to e nable the power relay. If power failures occur, system relay will be activated.

Link Lose

Set relay active if port disconnected, such as, no cable connected; cable break; opposing device fail.

Communication Lose

Set relay active if port of the ring pair disconnected.