6
Installation Troubleshooting
During installation, first test the fiber and twisted pair connections with
FiberAlert disabled. Then enable FiberAlert, if desired, just before final
installation. This will reduce the feature’s interference with testing.
To test McPC 100Mbps by itself, use the appropriate fiber patch cable. First,
connect McPC 100Mbps to the twisted pair device with a twisted pair cable.
Next, look a single strand of fiber from the transmit port to the receive port of
the media converter. Finally, verify that there are both twisted pair and fiber link
on the media converter.
Specifications
Environmental
Operating Temperature
32° - 104° F (0° - 40° C)
Storage Temperature
21° - 160° F (-6° - 71° C)
Humidity:
5 - 95% (non-condensing)
Electrical
Input Load
100/240V±10% ~ 50/60Hz, 0.1/0.05A
Dimensions
A single PCI slot module for use in a PC chassis.
IMC Networks Technical Support
Tel:
(949) 465 -3000 or (800) 624-1070 (in the U.S. and Canada);
+32-16-550880 (Europe)
Fax:
(949) 465-3020
E-Mail:
techsupp ort@imcnetworks.com
Web:
www.imcnetworks.com