Impulse DO3637R, DO4823R Back View Of Cabinet After Positioned On, Customer-Suppliedcounter/Base

Models: DO3623R DO3637R DO4837R DO4823R

1 27
Download 27 pages 6.81 Kb
Page 6
Image 6
BACK VIEW OF CABINET

VENTING INSTRUCTIONS FOR AIR INTAKE / EXHAUST - DO3637R

BACK VIEW OF CABINET

AFTER POSITIONED ON

CUSTOMER-SUPPLIED COUNTER/BASE

Warning: The minimum intake and exhaust areas must be allowed (as illustrated

below) or case temperatures may fluctuate beyond safe parameters.

NOTES:

1.BACK OF CABINET MUST BE VENTED A MINIMUM OF 13” x 13” FOR AIR INTAKE.

2.BACK OF CABINET MUST BE VENTED A MINIMUM OF 10 1/2” x 19” FOR AIR EXHAUST.

3.BACK OF CABINET MUST PROVIDE A MINIMUM OF 15” x 32” FOR MAINTENANCE ACCESS. THIS AREA (AS

DIMENSIONED BELOW) WILL ALLOW SERVICE TO SLIDE OUT CONDENSING UNIT.

4.SEE REFRIGERATION FUNDAMENTALS FOR VIEW OF CONDENSING UNIT AFTER SLIDE-OUT.

5. AIR INTAKE (ILLUSTRATED BELOW).

6.AIR EXHAUST (ILLUSTRATED BELOW).

9 1/2” CUSTOMER-SUPPLIED COUNTER/BASEFACIA ENCLOSURE

13” MINIMUM AIR INTAKE SPACE

15” MINIMUM MAINTENANCE ACCESS SPACE

9 1/2”

19” MINIMUM AIR EXHAUST SPACE

13” MINIMUM

AIR

INTAKE SPACE

32”

MINIMUM MAINTENANCE

 

 

ACCESS SPACE

10 1/2” MIN. Manual background AIR EXHAUST SPACE

R

888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com

6

Page 6
Image 6
Impulse DO3637R, DO4823R, DO4837R, DO3623R dimensions Back View Of Cabinet After Positioned On, Customer-Suppliedcounter/Base