VENTING INSTRUCTIONS FOR AIR INTAKE / EXHAUST - DO4837R

BACK VIEW OF CABINET

AFTER POSITIONED ON

CUSTOMER-SUPPLIED COUNTER/BASE

Warning: The minimum intake and exhaust areas must be allowed (as illustrated

below) or case temperatures may fluctuate beyond safe parameters.

NOTES:

1.BACK OF CABINET MUST BE VENTED A MINIMUM OF 13” x 25” FOR AIR INTAKE.

2.BACK OF CABINET MUST BE VENTED A MINIMUM OF 19” x 21” FOR AIR EXHAUST.

3.BACK OF CABINET MUST PROVIDE A MINIMUM OF 15” x 45” FOR MAINTENANCE ACCESS. THIS AREA (AS DIMENSIONED BELOW) WILL ALLOW SERVICE TO SLIDE OUT CONDENSING UNIT.

4.SEE REFRIGERATION FUNDAMENTALS FOR VIEW OF CONDENSING UNIT AFTER SLIDE-OUT.

5. AIR INTAKE (ILLUSTRATED BELOW).

6.AIR EXHAUST (ILLUSTRATED BELOW).

9 1/2”

13” MINIMUM AIR INTAKE SPACE

15” MINIMUM MAINTENANCE ACCESS SPACE

FACIA ENCLOSURE 9 1/2”

15” MINIMUM AIR EXHAUST SPACE

25” MINIMUM AIR

 

19”

MINIMUM

INTAKE

SPACE

2”

 

AIR EXHAUST

 

 

 

 

 

45” MINIMUM MAINTENANCE

SPACE

 

 

ACCESS SPACE

 

 

 

R

888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com

7

Page 7
Image 7
Impulse DO3623R, DO4823R, DO3637R dimensions Venting Instructions for AIR Intake / Exhaust DO4837R