F-41

 

 

F-41

 

 

 

TROUBLESHOOTING & REPAIR

 

 

THERMAL FAN/SNUBBER BOARD LED CHART

 

 

 

 

 

 

 

 

LED #

 

LED FUNCTIONS AND INDICATIONS

 

 

 

 

 

(Machine is ON)

 

 

 

 

 

 

 

1

 

Indicates fan should be running.

 

 

 

 

 

 

 

2

 

Indicates welding current is greater than 200 amps.

 

 

 

 

 

 

 

3

 

Indicates fan should be running due to heating of main

 

 

 

 

 

SCRs.

 

 

 

 

 

 

 

4

 

Indicates an open thermal fan thermistor or an open con-

 

 

 

 

 

nection between the thermistor and the thermal fan/snub-

 

 

 

 

 

ber board. See the Wiring Diagram (leads #319 and

 

 

 

 

 

#316).

 

 

 

 

 

 

 

5

 

Indicates a thermostat (choke or secondary) has opened.

 

 

 

 

 

The thermal protection light should also be illuminated.

 

 

 

 

 

 

 

6

 

Indicates the fan motor should be running. LED 6 should

 

 

 

 

 

be illuminated and the fan running when any

 

 

 

 

 

of the following LEDs are lit: LED 2, LED 3, LED 4, or

 

 

 

 

 

LED 5.

 

 

 

 

 

 

 