TROUBLESHOOTING & REPAIR

CONTROL BOARD TRANSFORMER (T3) TEST (continued)

FIGURE F.11 – CONTROL BOARD TRANSFORMER (T3) LEADS

CONTROL BOARD TRANSFORMER (T3)

CONTROL

BOX

PRIMARY LEADS

SECONDARY

LEADS #281

#255 AND #256

 

AND #282

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

TEST PROCEDURE

1.Disconnect the main AC input power to the DC-655 machine.

2.Remove the case top and sides.

3.Locate the control board transformer (T3) mounted on the rear of the control box. See Figure F.11.

4.Locate the transformer (T3) primary leads (#255 and $256). See Figure F.11 and the Wiring Diagram. Also locate the secondary leads (#281 and #282).

WARNING

ELECTRIC SHOCK can kill.

• Do not touch electrically hot parts.

5.Apply the correct three-phase input power to the DC-655 and turn the power switch (SW1) to the ON position.

6.Carefully check for 42 VAC at the secondary leads (#281 to #282). If 42 VAC is present, the control board transformer (T3) is good. If 42 VAC is missing or low, proceed to the next step.

7.Carefully check for 115 VAC at the primary leads (#255 and #256). If the 115 VAC is present but the secondary voltage (42 VAC) is missing or low, the T3 transformer may be faulty. Replace.

8.If the 115 VAC is NOT present at the prima- ry leads, check the associated switch (SW1) and wiring. See the Wiring Diagram.

9.Perform the Control Transformer (T2) Test.