ACCESSORIES

FIGURE C.4 - LN-8 OR LN-9 WIRE FEEDER CONNECTION TO THE IDEALARC DC-655

POWER SOURCE

 

 

 

 

 

 

 

21

 

 

TO LN-8 OR LN-9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT CABLE PLUG

 

 

 

 

 

 

 

CONTROL CABLE

 

+21- 21 41

4

2

31 32

75

76

77

 

 

 

 

 

 

 

C

}N.E.

 

 

 

 

 

 

AB

 

 

 

 

 

 

32

 

 

 

 

 

 

 

31

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

GND

 

NEGATIVE

 

 

POSITIVE

 

 

21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRODE CABLE

 

 

 

 

 

 

 

TO WIRE FEED UNIT

 

 

 

 

 

 

 

}TO WORK

 

 

 

 

 

 

REMOTE VOLTAGE SENSING LEAD

 

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

CONNECTING THE LN-8 OR LN-9 TO THE IDEALARC DC-655 (TERMINAL STRIP)

1.Set the Idealarc DC-655 POWER toggle switch to the OFF (0) position.

2.Disconnect main AC input power to the Idealarc DC-655.

3.Connect the wire feeder control cable leads to the Idealarc DC-655 terminal strip as shown in Figure C.4.

4.Connect the wire feeder control cable ground lead

to the frame terminal marked .

5.Extend wire feeder control cable lead #21 so it can be connected directly to the work piece.

a.Make a bolted connection using AWG #14 or larger insulated wire. Tape the bolted connec- tion with insulating tape.

b.An S-16586- X remote voltage sensing work lead is available for this purpose.

c.Keep the #21 lead electrically separate from the work cable circuit and connection.

d.Tape the #21 lead to work cable for ease of use.

6.Connect LN-9 wire feeder control jumpers on Voltage Control board. See LN-9 Operator’s Manual.

NOTE: The connection diagram shown in Figure C.4 shows the electrode connected for positive polarity. To change polarity:

a.Set the Idealarc DC-655 POWER toggle switch to the OFF (0) position.

b.Move the electrode cable to the negative (-) output terminal (High inductance or low inductance as needed).

c.Move the work cable to the positive (+) output terminal.

d.Connect control cable lead #21 to “+21” on the terminal strip.

7.Set the OUTPUT CONTROL switch to the “Remote” position and the OUTPUT TERMINALS switch to the “Remote” position.