F-24

F-24

TROUBLESHOOTING & REPAIR

MAIN TRANSFORMER (T1) VOLTAGE TEST (continued)

FIGURE F.7 - MAIN TRANSFORMER SECONDARY LEADS TO

COMMON BUS VOLTAGE CHECK

COMMON

BUS

CHOKE

SECONDARY

MAIN

LEADS (6)

TRANSFORMER

9. Test with an AC voltmeter for approximately

NOTE: The secondary voltages will vary if the

55 VAC from each of the six main trans-

input line voltages vary. If any one or more of the

former secondary leads to the common bus

voltage checks are incorrect, check for loose or

connected to the output choke. See Figure

faulty connections. See the Wiring Diagram. If

F.7.

the leads and connections are OK, the main

 

transformer may be faulty.

IDEALARC DC-655

Page 66
Image 66
Lincoln Electric DC-655 service manual Troubleshooting & Repair