NOTE: The connection diagram shown in Figure C.1 shows the electrode connected for positive polarity. To change polarity:

a. Set the Idealarc DC-655 POWER toggle

switch to the OFF (0) position.

b. Move the electrode cable to the negative (-)

output terminal. (High inductance or low

FIGURE C.2 – NA-5/-5R WIRE FEEDER CONNECTION TO THE IDEALARC DC-655

14-PIN RECEPTACLE

POWER SOURCE

 

CONTROL CABLE

 

FOR CONTROL CABLE

WITH 14 PIN MS-TYPE

PLUG CONNECTOR

21

TO NA-5/-5R

OR

 

 

INPUT CABLE PLUG

CONTROL CABLE

FOR CONTROL CABLE

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

 

inductance, as needed).

c.

Move the work cable to the positive (+) output

 

terminal.

d.

If connecting lead #21 to the terminal strip,

 

connect it to the +21 terminal (to match work

 

polarity). If work polarity changes back to

 

negative, lead #21 must be connected to the

 

-21 terminal.

e.

Reverse the leads on the back of the ammeter

 

and voltmeter in the automatic control box.

f.

If the automatic controls include a variable

 

voltage board, connect its jumper lead to pin

 

“L”. This will permit the inch down button to

 

operate. However, the jumper also disables

 

the cold starting/autostop feature of the auto-

 

matic controls. Only hot starting will be avail-

 

able.

6. Set the DC-655 OUTPUT CONTROL switch to the

“Remote” position and the OUTPUT TERMINALS

switch in the “Remote” position.

CONNECTING THE NA-5/-5R TO THE IDEALARC DC-655 (TERMINAL STRIP)

1.Set the Idealarc DC-655 POWER toggle switch to the OFF (0) position.

2.Disconnect main AC input power to the Idealarc DC-655.

3.Connect the wire feeder control cable leads to the Idealarc DC-655 terminal strip as shown in Figure C.2.

WITH TERMINAL STRIP

LEAD CONNECTORS

+21 - 21 41

4

2

31

32

75

76

77

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

32

 

 

 

 

 

 

 

31

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

GND

NEGATIVE

 

 

 

POSITIVE

 

 

21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BOLT TO CABLES FROM NA-5/-5R

 

 

 

 

 

 

 

WIRE CONTACT AS'BLY

 

 

 

 

 

 

 

TO WORK

REMOTE VOLTAGE SENSING LEAD

4.Connect the wire feeder control cable ground lead

to the frame terminal marked .

NOTE: The Idealarc DC-655 must be properly grounded.

5.Extend wire feeder control cable lead #21 so it can be connected directly to the work piece.

a.Make a bolted connection using AWG #14 or larger insulated wire. Tape the bolted connec- tion with insulating tape.

b.An S-16586-X remote voltage sensing work lead is available for this purpose.

c.Keep the #21 lead electrically separate from the work cable circuit and connection.

d.Tape the #21 lead to work cable for ease of use.

Return to Section TOC

Return to Master TOC

IDEALARC DC-655

Page 26
Image 26
Lincoln Electric service manual Set the Idealarc DC-655 Power toggle