Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
TROUBLESHOOTING & REPAIR
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM
CONSTANT VOLTAGE MIG
MINIMUM OUTPUT SETTING – NO LOAD
0 volts
20 volts | 2 ms |
This is the typical DC open circuit voltage waveform generated from a properly operating machine. Note that each vertical division represents 20 volts and that each horizontal divi- sion represents 2 milliseconds in time.
Note: Scope probes connected at
machine output terminals: (+) probe to positive terminal,
SCOPE SETTINGS
Volts/Div | 20V/Div. |
Horizontal Sweep | 2 ms/Div. |
Coupling | DC |
Trigger | Internal |
|
|