TROUBLESHOOTING & REPAIR

 

F-4

 

 

 

Observe Safety Guidelines

 

 

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

Major physical or electrical dam-

1.

Contact the Lincoln Electric

 

 

 

age is evident.

 

 

Service Dept. 1-800-833-9353.

 

 

 

 

 

 

 

The machine is dead - the input

1.

The power switch (S1) is in the

1. Check the power switch (S1)

contactor does not operate. The

 

ON position.

and associated leads and con-

pilot light is not lit.

 

2.

Check for blown or missing

nections.

See the

Wiring

 

 

Diagram.

 

 

 

 

 

fuses in the input lines.

 

 

 

 

 

 

 

 

 

 

3.

Check the three-phase input

2. Perform the

Control

Trans-

 

 

former Test.

 

 

 

 

 

line voltage at the machine.

 

 

 

 

 

 

 

 

 

 

 

The input voltage must match

 

 

 

 

 

 

the rating plate and reconnect

 

 

 

 

 

 

panel.

 

 

 

 

 

 

 

The input contactor operates, but

1.

Check the electrode and work

1. Perform the Internal Trigger

no welding output.

The 115 VAC

 

cables for loose or faulty con-

Circuit Test.

 

 

auxiliary supply is

present at the

 

nections.

2. Perform the Firing Board Test.

receptacle.

 

 

 

 

2. If the Thermal Protection Light

 

 

 

 

 

3. Perform the Main Transformer

 

 

 

is ON, the machine is overheat-

 

 

 

Test.

 

 

 

 

 

ed. Wait for the machine to

 

 

 

 

 

 

 

 

 

 

 

cool and remedy the cause of

4. Perform the SCR Output

 

 

 

the overheating problem. See

Bridge Test.

 

 

 

 

 

the Fan/Snubber Board LED

5. The control

board may be

 

 

 

Chart.

 

 

 

faulty. See Control Board LED

 

 

 

 

 

 

3.

Make certain either the output

Chart.

 

 

 

 

 

terminals switch is in the ON

 

 

 

 

 

 

position or the external gun

 

 

 

 

 

 

trigger circuit is functioning

 

 

 

 

 

 

properly.

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353.