F-6

F-6

 

TROUBLESHOOTING & REPAIR

 

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

 

 

The machine has welding output

1. Check the output control switch

1.

The output control potentiome-

but no control.

(SW3) for proper setting.

 

ter, output control switch (SW3)

 

2. If a

remote

control

cable is

 

or associated

wiring

may be

 

 

defective.

See the Wiring

 

used,

make

certain

the cable

 

 

 

Diagram.

 

 

 

 

and connections are good.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. Perform the Firing Board Test.

 

 

 

 

 

3.

Perform the

SCR

Output

 

 

 

 

 

 

Bridge Test.

 

 

 

 

 

 

 

 

4. The control

 

board

may be

 

 

 

 

 

 

faulty. See the Control Board

 

 

 

 

 

 

LED Chart.

 

 

 

 

 

 

 

The machine does not have maxi-

1. Check the three-phase input

1.

The output control potentiome-

mum output.

lines at the DC-655.

Make cer-

 

ter, output control switch (SW3)

 

tain the input voltages match

 

or associated wiring may be

 

the machine’s rating and recon-

 

defective.

See the Wiring

 

nect panel configuration.

 

Diagram.

 

 

 

 

2. Put the output control switch

2.

Perform the Main Transformer

 

(SW3) in the “Local” control

 

Test.

 

 

 

 

position. If

the problem is

3. Perform the Firing Board Test.

 

resolved, the remote unit or

 

 

 

 

 

 

 

wire feeder may be defective.

4.

Perform the SCR Bridge Test.

 

 

 

 

 

5. The control

 

board

may be

 

 

 

 

 

 

faulty. See the Control Board

 

 

 

 

 

 

LED Chart.

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353.

IDEALARC DC-655