FIELD INSTALLED OPTIONS

K1482-1 Digital Ammeter/Voltmeter Kit - Installs easily to the front control panel and provides digital display of actual welding voltage and amperage while welding. (Installation instructions are included with the kit).

K1483-1 Analog Ammeter/Voltmeter Kit - Installs easily to the front control panel and provides analog display of actual welding voltage and amperage while welding. (Installation instructions are included with the kit).

K1484-1 Dual Feeder Kit - This kit replaces the 14- Pin MS-receptacle panel on the lower case front of the DC-655. It provides two 14-PinMS-receptacles and a built in transfer circuit for connecting and operating two like-polarity wire feeders. European DC-655 mod- els can only use 42V feeders with this kit. (Installation instructions are included with the kit).

K1485-1 Cable Hanger Bracket - Mounts over stan- dard lift bale of the DC-655 and provides a cable hanger on both sides of the power source, each side capable of holding up to 100 ft. of weld cable. (Installation instructions are included with the kit).

K1486-1 Air Filter Kit - Removable metal filter easily slides in and out of a bracket which mounts to the front of the DC-655. Filter is designed to trap 80% of entering particles which are 5 microns, or larger, in size. (Installation instructions are included with the kit). Cannot be used with K1528-1 Dual process switch.

NOTE: A dirty air filter may cause the thermal protec- tion of the DC-655 to prematurely activate. Remove and blow out, or wash and dry, the filter every two months, or less if in extremely dirty conditions. Replace if necessary.

Undercarriage (K817P, K842) - The DC-655 is designed for use with the Lincoln K817P or K842 Undercarriage. Complete installation instructions are included with each undercarriage. When any of the undercarriages are installed, the DC-655 lift bail is no longer functional. Do not attempt to lift the machine with the undercarriage attached. The undercarriage is designed for moving the machine by hand only. Mechanized towing can lead to injury and /or damage to the DC-655.

REMOTE OUTPUT CONTROL

(K775 OR K857 WITH K864 ADAPTER)

An optional “remote output control” is available. This is the same remote control that is used on other Lincoln power sources (K775). The K775 consists of a control box with 28 ft (8.5m) of four conductor cable. This connects to terminals 75, 76, and 77 on the terminal strip and the case grounding screw so marked with the symbol on the machine. These terminals are locat- ed behind the cover panel on the lower connection panel of the DC-655. This control will give the same control as the output control on the machine.

The K857 has a 6-pin MS-style connector. The K857 requires a K864 adapter cable which connects to the 14-pin connector on the DC-655.

REMOTE CONTROL ADAPTER CABLE (K864)

STRAIGHT PLUG (14 PIN)

CABLE RECEPTACLE (6 SOCKET)

TO POWER SOURCE

TO: K857 REMOTE CONTROL

 

CABLE RECEPTACLE (14 SOCKET)

TO: LN - 7 WIRE FEEDERS

A “V” cable 12” (.30m) long to connect a K857 Remote Control (6 pin connector) with a wire-feeder (14-pin connector) and the machine (14-pin connector). If a remote control is used alone the wire-feeder connec- tion is then not used.

K1528-1 Dual Process Switch - (Cannot be used with K1486-1 Air Filter Kit) The Dual-Process Switch mounts easily to the front of the machine and is designed to provide a selection between left and right side output terminals. Each pair of output terminals can be switched to either the DC-655, high or low inductance terminals as desired. Wire feed unit cables and air carbon arc cables can be connected to either or both sides of the box and with proper connection can provide polarity change with just a switch change. Selecting one side only energizes those output studs and opens the other side. Installation instructions are included with the switch.)

K1611-1 Paralleling Kit - Provides interconnection of two DC-655 machines in parallel for doubling the cur- rent capacity of one machine. This “master” and “slave” connection configuration allows the “master” to control the balanced output of both machines. Individual protection circuits of both machines func- tion normally. (Installation instructions are included with the switch.)

IDEALARC DC-655