F-19

F-19

TROUBLESHOOTING & REPAIR

FIRING BOARD TEST (continued)

 

TABLE F.1 - LED 7, 8, 9 AND 10

 

 

 

 

 

 

IF

THEN

 

 

 

 

 

 

LED 7 is ON

32 VAC power is being supplied to the

 

 

 

firing board from leads #203 and

 

 

 

#204 connected to the phase angle

 

 

 

winding in the Main Transformer.

 

 

 

Normal is 32 VAC.

 

 

LED 7 is not lit or is dimmer than

The proper AC voltage may not be

 

 

the other LEDs

reaching the firing board. Check for

 

 

 

loose or faulty connections. Perform

 

 

 

the Main Transformer Test.

 

 

 

 

 

 

LED 8 is ON

32 VAC power is being supplied to the

 

 

 

firing board from leads #205 and #206

 

 

 

connected to the phase angle winding in

 

 

 

the Main Transformer.

 

 

LED 8 is not lit or is dimmer than

The proper AC power may not be

 

 

the other LEDs

reaching the firing board. Check for

 

 

 

loose or faulty connections. Perform

 

 

 

the Main Transformer Test.

 

 

 

 

 

 

LED 9 is ON

32 VAC power is being supplied to

 

 

 

the firing board from leads #207 and

 

 

 

#208 connected to the phase angle

 

 

 

winding in the Main Transformer.

 

 

LED 9 is not lit or is dimmer than

The proper AC power may not be

 

 

the other LEDs

reaching the firing board. Check for

 

 

 

loose or faulty connections. Perform

 

 

 

the Main Transformer Test.

 

 

 

 

 

 

LED 10 is ON

This indicates the trigger circuit is

 

 

 

activated at the 14-pin receptacle or

 

 

 

the terminal strip or that the Output

 

 

 

Terminal Switch (SW5) is closed.

 

 

 

 

 

IDEALARC DC-655

Page 61