F-7

F-7

 

 

TROUBLESHOOTING & REPAIR

 

 

Observe Safety Guidelines

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

 

The 115 VAC receptacle is not

1. The circuit breaker may be

1. The circuit breaker may be

working. The machine’s welding

tripped. Reset if necessary.

defective. Check

associated

output is normal.

2. Make sure the 115 VAC plug

wiring. See the Wiring Diagram.

 

 

 

 

 

 

and “load” is in good working

2. Check for 115 VAC at terminals

 

condition.

#31 and #32 on the terminal

 

 

strip. If 115 VAC is present at

 

 

the terminal strip, check the

 

 

wiring

between the

terminal

 

 

stirp, the circuit breaker and the

 

 

115 VAC receptacle. If 115 VAC

 

 

is NOT present at the terminal

 

 

strip,

perform

the

Main

 

 

Transformer Test.

 

 

 

 

3. The 115 VAC receptacle may

 

 

be defective.

 

 

 

 

 

 

 

 

When not welding for a period of

1. This may be a normal condition.

 

 

 

 

time, the machine shuts down.

See the Idle Shut Down Timer.

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353.