Lincoln Electric DC-655 service manual Active SCR Test, Test Procedure

Models: DC-655

1 109
Download 109 pages 42.44 Kb
Page 81
Image 81

to Section TOC

to Master TOC

F-39

F-39

TROUBLESHOOTING & REPAIR

ACTIVE SCR TEST (continued)

FIGURE F.16 – THERMAL FAN/SNUBBER BOARD AND FIRING BOARD PLUG LOCATIONS

Return

Return to Section TOC

Return

Return to Master TOC

THERMAL FAN / SNUBBER

LED2

LED5

LED1

L10124-[ ]

LED6

LED4

LED3

PLUG J20

 

 

PLUG J9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Return to Section TOC

Return to Master TOC

LED7

LED8

LED9

 

J5

 

 

 

 

LED1

 

LED2

G2699-[ ]

 

 

 

 

 

 

 

 

LED10

J6

 

 

 

 

LED3

 

LED4

 

J7

 

 

LED6

 

J4

LED5

 

 

 

 

 

 

 

 

 

 

FIRING BOARD

 

Return to Section TOC

Return to Master TOC

TEST PROCEDURE

1.Disconnect the main AC input power to the machine.

2.Locate and disconnect plug J9 from the thermal fan/snubber board and plug J5 from the firing board. See Figure F.16.

3.Remove the red insulating paint from the heat sink test points. See Figure F.17. DO NOT DISASSEMBLE THE HEAT SINKS.

IDEALARC DC-655

Page 81
Image 81