Lincoln Electric DC-655 service manual Main Transformer T1 Voltage Test

Models: DC-655

1 109
Download 109 pages 42.44 Kb
Page 65
Image 65

Return to Section TOC

Return to Master TOC

F-23

F-23

TROUBLESHOOTING & REPAIR

MAIN TRANSFORMER (T1) VOLTAGE TEST (continued)

FIGURE F.6 – INPUT CONTACTOR AND PRIMARY LEADS

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

TEST PROCEDURE

1.Disconnect the main input power from the DC-655.

2.Inspect the input contactor, reconnect panel and primary leads to the main trans- former for loose or faulty connections. See Figure F.6. Remove the case sides.

3.Confirm that the reconnect panel is config- ured correctly for the three-phase AC input power supplied to the DC-655. See the connection diagram located on the inside of the input box assembly.

4.Connect the correct AC three-phase input power to the DC-655 machine.

WARNING

ELECTRIC SHOCK can kill.

• Do not touch electrically hot parts.

5.Turn the power switch (SW1) to the ON position.

6.Make sure the input contactor (CR1) ener- gizes.

7.Test with an AC voltmeter for the proper main AC input voltages applied to the line side of the input contactor (CR1). See the Wiring Diagram. If the correct voltages are not present at the line side of the input contactor, check the input fuses and leads.

a.L1 to L2

b.L2 to L3

c.L1 to L3

8.Test with an AC voltmeter for the proper AC input voltages at the output side of the input contactor (CR1). See the Wiring Diagram. If the correct voltages are not present, perform the Input Contactor

Test.

a.T1 to T2

b.T2 to T3

c.T1 to T3

Return to Section TOC

Return to Master TOC

IDEALARC DC-655

Page 65
Image 65
Lincoln Electric DC-655 service manual Main Transformer T1 Voltage Test, Figure F.6 Input Contactor and Primary Leads