TROUBLESHOOTING & REPAIR
MAIN TRANSFORMER (T1) VOLTAGE TEST (continued)
FIGURE F.6 – INPUT CONTACTOR AND PRIMARY LEADS
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
TEST PROCEDURE
1.Disconnect the main input power from the
2.Inspect the input contactor, reconnect panel and primary leads to the main trans- former for loose or faulty connections. See Figure F.6. Remove the case sides.
3.Confirm that the reconnect panel is config- ured correctly for the
4.Connect the correct AC
WARNING
ELECTRIC SHOCK can kill.
• Do not touch electrically hot parts.
5.Turn the power switch (SW1) to the ON position.
6.Make sure the input contactor (CR1) ener- gizes.
7.Test with an AC voltmeter for the proper main AC input voltages applied to the line side of the input contactor (CR1). See the Wiring Diagram. If the correct voltages are not present at the line side of the input contactor, check the input fuses and leads.
a.L1 to L2
b.L2 to L3
c.L1 to L3
8.Test with an AC voltmeter for the proper AC input voltages at the output side of the input contactor (CR1). See the Wiring Diagram. If the correct voltages are not present, perform the Input Contactor
Test.
a.T1 to T2
b.T2 to T3
c.T1 to T3