TROUBLESHOOTING & REPAIR

MAIN TRANSFORMER (T1) VOLTAGE TEST (continued)

FIGURE F.9 - FIRING BOARD PLUG J5 PINS

Return

Return to Section TOC

Return

Return to Master TOC

LED7

LED8

LED9

 

 

 

(205) 8

 

 

(206) 7

 

 

(207) 6

 

 

(208) 5

LED1

 

LED2

4

 

3

 

 

G2699-[ ]

2

 

 

 

1

 

 

LED10

 

LED3

 

LED4

 

LED6

LED5

FIRING BOARD

J5

16 (204)

15 (203)

14

13 (231)

12 (215)

11

10 9

J6

J7

J4

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

15.Locate plug J5 on the firing board. See Figure F.9.

WARNING

ELECTRIC SHOCK can kill.

Do not touch electrically hot parts.

16.Turn on the DC-655 and check for approx- imately 32 VAC at the following leads and pins at plug J5. These are the phase angle winding voltages. See Fig. F.9.

Plug J5 pin-15 (lead #203) to pin-16 (lead #204)

Plug J5 pin-8 (lead #205) to pin-7 (lead #206)

Plug J5 pin-6 (lead #207) to pin-5 (lead #208)

17.Locate plug J13 on the optional digital meter board. If a digital meter board is not in place, plug J13 will not be used but will be present in the harness. Check the fol- lowing voltages at the appropriate leads and pin locations.

10 VAC Plug J13 pin-1 (lead #331) to pin-2 (lead #332)

10 VAC Plug J13 pin-4 (lead #333) to pin-5 (lead #334)

42 VAC Plug J13 pin-3 (lead #335) to pin-6 (lead #336)

18.If the correct primary voltages are applied to the main transformer and any of the sec- ondary voltages are missing or not correct, the transformer may be faulty.

NOTE: Always check the wiring between the transformer windings and the test points before replacing the transformer.

IDEALARC DC-655

Page 68