TROUBLESHOOTING & REPAIR

NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM

CONSTANT CURRENT MODE – NO LOAD

0 volts

50 volts

2 ms

This is the typical DC open circuit voltage waveform generated from a properly operating machine. Note that each vertical division represents 50 volts and that each horizontal divi- sion represents 2 milliseconds in time.

Note: Scope probes connected at

machine output terminals: (+) probe to positive terminal, (-) probe to neg- ative high inductance terminal.

SCOPE SETTINGS

Volts/Div

50V/Div.

Horizontal Sweep

2 ms/Div.

Coupling

DC

Trigger

Internal

 

 