Electrical connection

Electrical connection

!Ovens with a three-pole power supply cable are designed to operate with alternated current at the supply frequency and voltage indicated on the data plate (at the bottom of the oven dashboard). The earthing conductor of the cable is the yellow-green conductor.

Two types of connection are provided:

Connection n° 1

coloured Red. Connect Blue wire to terminal marked

“N” or coloured Black. If a 13 amp plug (BS 1363) is GB used it must be fitted with a 13 amp fuse.

A 15 amp plug must be protected by a 15 amp fuse, either in the plug or adaptor or at the distribution board.If you are in any doubt about the electrical supply to your machine, consult a qualified electrician before use.

How to connect an alternative plug

Connecting the power supply cable to the mains.

Fit a normalized plug to the cable, which corresponds to the load indicated on the data plate; if the cooker is connected directly to the mains, an omnipolar circuit- breaker with a minimum opening of 3 mm between the contacts, suitable for the load indicated and complying with current directives, must be installed between the appliance and the mains (the earthing wire must not be interrupted by the circuit-breaker).

The wires in this mains lead are coloured in accordance with the following code:

BLUE “NEUTRAL” (N)

BROWN “LIVE” (L)

GREEN AND YELLOW “EARTH” (E)

GREEN &

YELLOW

BROWN

13 amp fuse

 

BLUE

CROSS-BAR

 

CORD GRIP

The power supply cable must be positioned so that it does not exceed room temperature by 50°C at any point of its length. Before making the connection check that:

the circuit breakers or fuses of the home system can support appliance load (see data plate);

the power supply system has an efficient earthing connection which complies with the provisions of current regulations and the law;

there is easy access to the socket or the omnipolar

circuit-breaker once the cooker has been installed.

!do not use reducers, adapters or shunts as these could cause heating or burning.

Disposing of the appliance

When disposing of the appliance please remove the plug by cutting the mains cable as close as possible to the plug body and dispose of it as described above.

!The plug and socket must be easily accessible.

DATA PLATE

width cm 43.5

Dimensions height cm 32 depth cm 40

Volume

lt. 56

Connection n° 2

Disposing of the plug.

!THIS APPLIANCE MUST BE EARTHED. Ensure that before disposing of the plug itself, you make the pins unusable so that it cannot be accidentally inserted into a socket. Instructions for connecting cable to an alternative plug:

!the wires in the mains lead are coloured in accordance with the following code:

Green & Yellow

-Earth

Blue

-Neutral

Brown

-Live

If the colours of the wires in the mains lead do not correspond with the coloured markings identifying the terminals in your plug, proceed as follows.

Connect Green & Yellow wire to terminal marked “E” or 6 or coloured Green or Green & Yellow.

Connect Brown wire to terminal marked “L” or

Electrical connections

ENERGY LABEL

voltage: 230 -240V ~ 50Hz m axim um power absorbed 2250W -2400W

Directive 2002/40/EC on the label of electric ovens .

Standard EN 50304

Energy consum ption for N atural convection – heating mode: Convection mode

Declared energy consum ption for Forced convection C lass – heating

m ode: Disposing of the plug. Multi-cooking

This appliance conform s to the following European Econom ic Com m unity directives:

-2006/95/EEC of 12/12/06 (Low Voltage) and subsequent amendm ents;

-89/336/EEC of 03/05/89

(Electrom agnetic Com patibility) and subsequent am endments;

-93/68/EEC of 22/07/93 and subsequent am endments .