ENGLISH

USER MANUAL

MAINTENANCE

The lifespan of the machine and its maximum operating safety are ensured by correct and regular maintenance.

The following table provides the scheduled maintenance. The intervals shown may vary according to particular working conditions, which are to be defi ned by the person in charge of the maintenance.

WARNING!

To carry out maintenance procedures, the machine must be off and, if necessary, the batteries must be disconnected.

Moreover, carefully read the instructions in the Safety paragraph.

All scheduled or extraordinary maintenance procedures must be performed by qualifi ed personnel, or by an authorised Service Center.

This Manual describes only the easiest and most common maintenance procedures.

NOTE

For other maintenance procedures shown in the Scheduled Maintenance Table, refer to the Service Manual that can be consulted at any Service Center.

SCHEDULED MAINTENANCE TABLE

Procedure

Every 10 hours

Every 50 hours

Every 200

Every 400

 

 

 

hours

hours

 

 

 

 

 

Battery charger cable check

 

 

 

 

 

 

 

 

 

Side and main broom height check and adjustment

 

 

 

 

 

 

 

 

 

Skirt height and operation check

 

 

 

 

 

 

 

 

 

Dust fi lter cleaning and integrity check

 

 

 

 

 

 

 

 

 

Hopper gasket check

 

 

 

 

 

 

 

 

 

Filter shaker operation check

 

 

(*)

 

 

 

 

 

 

Drive belt and clutch visual inspection

 

 

(*)

 

 

 

 

 

 

Drive system belt tensioner adjustment

 

 

(*)

 

 

 

 

 

 

Nut and screw tightening check

 

 

(*) (1)

 

 

 

 

 

 

Motor carbon brush check or replacement

 

 

 

(*)

 

 

 

 

 

(*): For the relevant procedure, see the Service Manual.

(1): And after the fi rst 8 hours.

BATTERY CHARGER CABLE CHECK

Carefully check the battery charger cable (18) and the relevant plug for wear, cuts, cracks or other damages. If the battery charger cable or the relevant plug is damaged, contact the Nilfi sk-Advance Service Center.