Indesit KP9 F11 S/G S manual GB Installation, Positioning and levelling, Electrical connection

Models: KP9 F11 S/G S

1 12
Download 12 pages 28.84 Kb
Page 4
Image 4
GB Installation

GB Installation

!Before placing your new appliance into operation please read these operating instructions carefully. It contains important information concerning the safe installation and operation of the appliance.

!Please keep these operating instructions for future reference. Make sure that the instructions are kept with the appliance if it is sold, given away or moved.

!The appliance must be installed by a qualified professional in accordance with the instructions provided.

!Any necessary adjustment or maintenance must be performed after the cooker has been disconnected from the electricity supply.

The cookers have the following technical specifications:

Category: II 2H3+

Room ventilation

The appliance may only be installed in permanently- ventilated rooms, according to current national legislation. The room in which the appliance is installed must be ventilated adequately in order to provide as much air as is needed by the normal gas combustion process (the flow of air must not be lower than 2 m3/h per kW of installed power). The air inlets, protected by grilles, should have a duct with an inner cross section of at least 100 cm2 and should be positioned so that they are not liable to even partial obstruction (see figure A).

These inlets should be enlarged by 100% - with a minimum of 200 cm2 - whenever the surface of the hob is not equipped with a flame failure safety device. When the flow of air is provided in an indirect manner from adjacent rooms (see figure B), provided that these are not communal parts of a building, areas with increased fire hazards or bedrooms, the inlets should be fitted with a ventilation duct leading outside as described above.

!The liquefied petroleum gases are heavier than air and collect by the floor, therefore all rooms containing LPG cylinders must have openings leading outside so that any leaked gas can escape easily. LPG cylinders, therefore, whether partially or completely full, must not be installed or stored in rooms or storage areas which are below ground level (cellars, etc.). Only the cylinder being used should be stored in the room; this should also be kept well away from sources of heat (ovens, chimneys, stoves) which may cause the temperature of the cylinder to rise above 50°C.

Positioning and levelling

!The appliance may be installed alongside any cupboards whose height does not exceed that of the hob surface.

!Make sure that the wall in contact with the back of the appliance is made from a non-flammable, heat-resistant material (T 90°C).

To install the appliance correctly:

Place it in the kitchen, the dining room or the studio flat

(not in the bathroom).

If the top of the hob is higher than the cupboards, the

appliance must be installed at least 500 mm away from them. Category: II 2H3+ • If the cooker is installed

 

 

 

 

 

 

 

 

underneath a wall cabinet, there

 

 

 

HOOD

 

 

 

 

 

 

 

 

 

 

 

must be a minimum distance of 420

 

 

 

Min. 600mm.

 

 

650mm. with hood mm. without hood

 

 

 

 

 

 

mm between this cabinet and the

 

420mm.

 

 

420mm.

 

 

 

 

 

top of the hob.

 

Min.

 

 

 

Min.

min. min.700

 

This distance should be increased

 

 

 

 

 

 

 

 

to 700 mm if the wall cabinets are

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

flammable (see figure).

 

 

 

 

 

 

 

Do not position blinds behind the cooker or less than 200 mm away from its sides.

Any hoods must be installed in accordance with the instructions listed in the relevant operating manual.

A

Examples of ventilation holes for comburant air.

A

Adjacent

Room to be

Room

Vented

Enlarging the ventilation slot

between window and floor.

B

 

Levelling

If it is necessary to level the appliance, screw the adjustable feet into the places provided on each corner of the base of the cooker (see figure).

!After prolonged use of the appliance, it is advisable to open a window or increase the speed of any fans used.

Disposing of combustion fumes

The efficient disposal of combustion fumes should be guaranteed using a hood which is connected to a safe and efficient natural suction chimney, or using an electric fan which begins to operate automatically every time the appliance is switched on (see figure).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

In a chimney stack or branched flue.

Directly to

(exclusively for cooking appliances)

the Outside

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical connection

THE APPLIANCE MUST BE EARTHED

ATTENTION: This appliance has a maximum power exeeding 3kW; it is therefore necessary for it to be connected to a socket able to support a rated current higher than 13A (the appliance rated current is 15A). Connecting the supply cable to the mains electricity supplyA13.Aplug in compliance whit BS 1362 is not suitable.

Install a standardised plug corresponding to the load indicated on the appliance data plate (see Technical data table). The appliance must be directly connected to the mains using an omnipolar switch with a minimum contact opening of 3 mm installed between the appliance and the mains.

4

Page 4
Image 4
Indesit KP9 F11 S/G S GB Installation, Positioning and levelling, Electrical connection, Category II 2H3+ Room ventilation