- Earth

The switch must be suitable for the charge indicated and must comply with current electrical regulations (the earthing wire must not be interrupted by the switch). The supply cable must be positioned so that it does not come into contact with temperatures higher than 50°C at any point.

Before connecting the appliance to the power supply, make sure that:

The appliance is earthed and the plug is compliant with the law.

The socket can withstand the maximum power of the appliance, which is indicated by the data plate.

The voltage is in the range between the values indicated on the data plate.

The socket is compatible with the plug of the appliance.

If the socket is incompatible with the plug, ask an authorised technician to replace it. Do not use extension cords or multiple sockets.

!Once the appliance has been installed, the power supply cable and the electrical socket must be easily accessible.

!The cable must not be bent or compressed.

!The cable must be checked regularly and replaced by authorised technicians only.

!The manufacturer declines any liability should these safety measures not be observed.

Important: the wires in the mains lead are coloured in accordance with the following code:

Green & Yellow

- Earth

Blue

- Neutral

Brown

- Live

As the colours of the wires in the mains lead may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:

Connect the Green & Yellow wire to terminal marked “E

or - Live or coloured Green or Green & Yellow.

Connect the Brown wire to the terminal marked “L” or coloured Red.

Connect the Blue wire to the terminal marked “N” or coloured Black.

FAILURE TO OBSERVE THE ACCIDENT-PREVENTION REGULATIONS RELIEVES THE MANUFACTURER OF ALL LIABILITY.

Replacing the cable

Use a rubber cable of the type H05VV-F with a cross section of 3 x 1.5 mm². The yellow-green earth wire must be 2 ÷ 3 cm longer than the other wires.

Gas connection

 

GB

Connection to the gas network or to the gas cylinder

may be carried out using a flexible rubber or steel hose,

 

 

in accordance with current national legislation and after

 

making sure that the appliance is suited to the type of gas

 

with which it will be supplied (see the rating sticker on the

 

cover: if this is not the case see below). When using liquid

 

gas from a cylinder, install a pressure regulator which

 

complies with current national regulations.

 

!Make sure that the gas supply pressure is consistent with the values indicated in the Table of burner and nozzle specifications (see below). This will ensure the safe operation and durability of your appliance while maintaining efficient energy consumption.

Gas connection using a flexible rubber hose

Make sure that the hose complies with current national legislation. The internal diameter of the hose must measure: 8 mm for a liquid gas supply;13 mm for a methane gas supply.

Once the connection has been performed, make sure that the hose:

Does not come into contact with any parts which reach temperatures of over 50°C.

Is not subject to any pulling or twisting forces and that it is not kinked or bent.

Does not come into contact with blades, sharp corners or moving parts and that it is not compressed.

Is easy to inspect along its whole length so that its condition may be checked.

Is shorter than 1500 mm.

Fits firmly into place at both ends, where it will be fixed using clamps which comply with current regulations.

!If one or more of these conditions is not fulfilled or if the cooker must be installed according to the conditions listed for class 2 - subclass 1 appliances (installed between two cupboards), the flexible steel hose must be used instead

(see below).

Connecting a flexible jointless stainless steel pipe to a threaded attachment

Make sure that the hose and gaskets comply with current national legislation. To begin using the hose, remove the hose holder on the appliance (the gas supply inlet on the appliance is a cylindrical threaded 1/2 gas male attachment).

!Perform the connection in such a way that the hose length does not exceed a maximum of 2 metres, making sure that the hose is not compressed and does not come into contact with moving parts.

Checking the connection for leaks

When the installation process is complete, check the hose fittings for leaks using a soapy solution. Never use a flame.