Installation
WARNING: Before installation, check that the gas type (natu- ral gas or LPG/Propane) of the cooker is suitable for the gas type available to the installation. It is extremely dangerous to use the wrong gas type with any appliance, as fire or serious injury can result.
These instructions have been prepared for use by authorised persons. This unit must only be installed by an authorised person.
This appliance must not be installed in marine craft or recrea- tional vehicles.
Compliance with standards
This cooktop must be installed in accordance with the re- quirements of local gas and electrical authorities, as well as the latest published versions of the following standards:
AS/NZS 5601 Gas Installation code
SAA Wiring Rules
Dimensions of cutout
The following diagram indicates the dimensions of the re- quired cutout.
In placing the cooktop, suitable insulation between the cook- top undersurface and the top of the bench should be used.
Wherever possible, the cooktop should be secured to the benchtop using clamps.
|
|
| 555 mm |
| |
|
|
|
|
| |
55 | mm |
|
| mm | |
475 | |||||
| |||||
|
|
| |||
|
|
|
|
|
INSTALLER: Please also ensure that the duplicate data label supplied, be affixed in a suitable easily accessible location such as an adjacent cupboard or drawer, for future reference.
Dimensions (mm) | PZ640 | PZ750 |
length (side to side) | 600 | 750 |
width (front to back) | 510 | 510 |
depth | 44 | 44 |
Fitting the cooktop into cabinetry
The following minimum clearances to combustible materials must be observed:
Minimum clearance from edge of burner to side wall must be 200 mm.
Minimum clearance from edge of burner to rear wall must be 200 mm.
Minimum clearance from top of highest burner to cupboard above hob burners must be 600 mm.
Fixing to the housing unit
Proceed with fixing to the housing unit as follows (see figure above).
Mount the hooks, partly tightening the screws into the holes.
Position the sealing gasket approximately
Insert the hob into the cutout, making sure it is positioned centrally and that the edge adheres to the sealant
Position the hooks correctly, as shown in the figure, and then tighten the screws to hold them in place.
Range hoods
Range hoods and overhead exhaust fans must be installed according to manufacturers’ instructions but in no case shall clearance from hob burners be less than 600 mm for range hoods and 750 mm for overhead exhaust fans.
Adjacent cabinetry
It is recommended that the adjacent kitchen surfaces should be capable of withstanding temperatures of 100°C.
4