RS-232 terminal Product Interface specifications
Communication configuration
To control the projector from an LCD control panel, connect an
Setting | Value |
Bits per second | 115,200 |
Data bits | 8 |
Parity | None |
Stop bits | 1 |
Flow control | None |
Emulation | VT100 |
|
|
Command format
All commands consist of 3 alpha characters followed by a request, all enclosed in “greater than” and “less than” signs. The request can be a read request (indicated by a “?”) or a write request (indicated by 1 to 4 ASCII digits).
A read request format: <AAA?> where
<starts the command
AAA denotes the command
? denotes the read request
> ends the command
A write request example: <AAA=####> where
<starts the command
AAA denotes the command
=#### denotes the value to be written (leading zeros not necessary)
>ends the command
Some commands have ranges, while others are absolute. If a number greater than the maximum range is received, it is automatically set to the maximum number for that function. With absolute settings, “0” is off,
Refer to the support section of our website for detailed information on the Product Interface formats.