InFocus LP840, LP860, LP850 manual LED Behavior, LED color/behavior, Meaning

Models: LP850 LP840 LP860

1 60
Download 60 pages 13.05 Kb
Page 46
Image 46
LED Behavior

LP840-850-860 User's Guide-02.fm Page 44 Friday, February 25, 2005 12:58 PM

LED Behavior

LED color/behavior

Meaning

 

 

Power: blinking green

The power switch has been toggled

Temp: N/A

on and the software is initializing, or

Lamp: N/A

the projector is powering down and

 

the fans are running to cool the lamp.

 

 

Power: blinking green (once)

Power Save or Screen Save.

Temp: N/A

 

Lamp: N/A

 

 

 

Power: solid green

The power switch has been toggled

Temp: N/A

on and the software has initialized or

Lamp: N/A

the projector has been powered off

 

via the remote.

 

 

Power: solid green

If Temp and Lamp are flashing simulta-

Temp: blinking red

neously, the filter hasn’t been cleaned

Lamp: blinking red

in 100 hrs.

 

If Temp and Lamp are flashing simulta-

 

neously (twice), the cooling air filter

 

may be dusty. Please see “Cleaning

 

the dust filter” on page 42.

 

If Temp and Lamp are flashing alter-

 

nately, the projector is below temper-

 

ature specifications. Please use the

 

projector in an environment between

 

0°C/32°F to 35°C/95°F. Contact

 

Technical Support if the problem per-

 

sists.

 

 

Power: solid red

Lamp won’t strike (blinks one time)

Temp: N/A

Lamp has exceeded lamp hours limit

Lamp: blinking red

(blinks two times)

 

Lamp has failed (blinks three times)

 

Lamp door is open (blinks four times)

 

Turn off the projector and wait one

 

minute, then turn the projector on

 

again. If the projector has exceeded

 

its lamp life limit, replace the lamp

 

and reset the lamp timer. Please con-

 

tact Technical Support if the problem

 

persists.

 

 

Power: solid red

Fan failure. Make sure the vents aren’t

Temp: blinking red

blocked. Contact Technical Support if

Lamp: N/A

the problem persists.

 

 

Power: solid red

The projector is overheating. Make

Temp: solid red

sure the vents aren’t blocked. Con-

Lamp: N/A

tact Technical Support if the problem

 

persists.

 

 

Power: solid red

Unidentified error. Please contact

Temp: N/A

Technical Support.

Lamp: N/A

 

 

 

44

Page 46
Image 46
InFocus LP840, LP860, LP850 manual LED Behavior, LED color/behavior, Meaning