DESCRIPTION

The LCN Presence Sensor (PN: 750182-00) is a self-monitored ready overhead-mounted diffused active infrared

 

 

sensing device that provides detection for the triggering of automatic swing door safety functions. When used with

 

LCN’s lockout devices, the sensor is programmed to allow two different fields of detection - one for detection when

 

the door is in the fully closed position and the other for detection when the door is fully open. While the door is in

 

the fully open position, the Presence Sensor extends its coverage back through the threshold area of the doorway,

 

to provide coverage that will overlap with LCN’s motion sensors.

 

As with all of LCN’s programmable sensing devices, full adjustability is achieved with the use of LCN’s hand-held

 

remote control unit. This allows alteration of all of the available functions as well as for inquiry of existing settings.

 

Should the need arise; the Presence Sensor may also be tuned by means of two sensor-mounted buttons

 

contained on the PC Board within the unit. With these two buttons, the Presence Sensor’s field of detection can be

 

altered without the use of the hand-held remote. If a complete door-mounted safety sensor (DMSS) system is not

 

used in addition to the Presence Sensor, LCN recommends the use of a lockout safety beam to allow safety

 

signaling if the zone is entered during a door closing cycle.

TECHNICAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installation Height - Variable

9’-0” max. (recommended 6’-6” to 8’-0”)

 

SPECIFICATIONS

 

Mounting Angles

 

 

 

 

 

 

 

 

 

 

 

 

Presence Sensor only

+5°, +10° (factory default setting: +5°)

 

 

 

Presence Sensor with BodyMount

0°, +5°, +10°

 

 

 

 

 

 

 

 

Power Supply

12 to 24 V AC / DC +/- 10%

 

 

 

 

 

Frequency

50-60 Hz

 

 

 

 

 

Output

Max. Voltage at contacts: 60V DC / 125V AC

 

 

 

 

 

 

Max. Current at contacts: 1 A

 

 

 

 

 

 

 

 

Max. switching power: 30 W (DC), 60 VA (AC)

 

 

 

Relay Hold Time

0.5 to 9 seconds

 

 

 

 

 

Operating Temperature

-22°F to +140°F

 

 

 

 

 

Immunity

Immune to electrical and radio frequency interference

 

 

 

Cable

4’- six conductor cable

 

 

 

 

 

Weight

1lb. 11 oz. (765g)

 

 

 

 

 

Dimensions

11.8”L (305 mm.) x 1.9”H (51 mm.) x 1.9”W (46 mm.)

 

 

 

Material

Aluminum & ABS plastic

 

 

 

 

 

Housing Color

Black anodized aluminum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMPONENT ID

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Left Lens

 

 

 

 

 

Red LED

 

 

 

Right Lens

 

 

 

 

 

 

 

 

 

 

 

 

Left End Cap

 

 

 

 

 

 

 

 

Right End Cap

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Center Eye Shield

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4’ Cable

 

INSTALLATION

TIPS

‰ The sensor must be

‰ The sensor must not have

‰ The sensor should be

firmly fastened to

any unwanted objects likely

mounted flush with bottom of

prevent vibration.

to move or vibrate in its

door header.

 

path.

 

 

 

 