MECHANICAL ADJUSTMENTS
Once all installation, wiring and cabling procedures have been completed, mechanical adjustments can be made. Please note that further adjustments may be required after powering and walk testing the detection field.
Aside from placement on the header, the only mechanical adjustment that may be made to the sensor is the angle adjustment. The Presence Sensor is factory
1.To change the angle setting the end caps, lenses, and center eye shield must be removed (as shown on page 2). The terminal block must also be removed if it has been wired. Once removed release the white clips, as shown below, and rotate outward to remove the PCB as shown in pictures 12 & 13.
12 | 13 |
2.Once the PCB is completely removed from the housing, the angle position may be changed. There are two clips per Presence Sensor and the angle must match for each clip on the same PCB. The positions are shown below.
0° | 5° | 10° |
Factory Default
3.Slide the left and right lens back into place and proceed with
14
POWER-UP PROCEDURES
1.Upon completion of mechanical and electrical installation, apply 12 to 24 V AC / DC +/- 10% to the Presence Sensor, with the door in the closed position. The Presence Sensor will flash a green LED at a rate of 2 Hz, then it will expire upon a successful
NOTE: If applying the Presence Sensor to a door control that requires a learn cycle upon powering, it is recommended to allow the doors to complete a learn cycle before applying power to the Presence Sensor.
2.Activate the door to the full open position. The Presence Sensor will once again flash the green LED and will execute a
NOTE: Always be sure to refer to the applicable lockout User’s Guide for more detailed information.