PRESENCE

Row 1 (spots 1 through 6), are on during open door position and off during closed door position.

SENSOR DEPTH

PATTERNS -

 

Cont.

 

 

 

(4) Deep Without Row 1

(5) Middle Without Row 1

(6) Limited Without Row 1

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

1

2

3

4

5

6

 

 

 

 

 

 

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

TROUBLE- SHOOTING

PROBLEM

PROBABLE CAUSE

CORRECTIVE ACTION

 

 

 

Presence Sensor will not

1. Improper input voltage

1. Check terminals 1 & 2 for proper voltage

set-up upon initial powering

2. Presence Sensor is in detection

24 V AC/DC + 10%.

 

3. Potential interferences from high

2. Make certain that the field of detection is all

 

intensity lighting

clear during the set-up and that all lenses

 

 

are installed on the Presence Sensor. If

 

 

detection is encountered upon initial set-up,

 

 

the Presence Sensor will continuously flash

 

 

Green at + 2 Hz. The Presence Sensor will

 

 

also not set-up if permanent stationary

 

 

objects are extremely close to the sensor.

 

 

Ensure that, not only is the detection field all

 

 

clear, but that the sensor is mounted

 

 

properly (using the Presence Sensor

 

 

mounting block if necessary).

 

 

3. Ensure that no high intensity lighting is in

 

 

the immediate area of the sensor.

Door will not open once set-

1. Presence Sensor is in detection.

1. Ensure that there is no detection occurring

up has been completed.

2. Improper wiring

at the Presence Sensor. If the Red LED is

 

3. Lockout safety beams are in

on steady, there is detection. Make sure

 

detection

there have been no changes in the field of

 

4. Improper relay output configuration

detection since set-up. If permanent

 

 

changes have occurred, launch a new set-

 

 

up and re-test door.

 

 

2. Remove the output wires (common,

 

 

normally open, normally closed) from the

 

 

Presence Sensor. CAUTION – there may

 

 

possibly be no safety on the door when

 

 

this test is performed. Activate the door

 

 

control, if the door opens, the fault exists

 

 

with Presence Sensor or related wiring. If

 

 

door does not open, the faults may exist

 

 

with the door control or it’s related wiring.

 

 

3. Ensure proper relay output setting. Refer to

 

 

page 6. Typically, relay setting should be

 

 

“Normally Open”. This means the relay

 

 

would close upon detection.

75.5255.02 XXXXXXXX

 

7940-8770 LCN

Page 10 of 11

Page 11
Image 11
Ingersoll-Rand 7940-8770 TROUBLE- Shooting Problem Probable Cause Corrective Action, Presence Sensor. Caution there may

7940-8770 specifications

The Ingersoll-Rand 7940-8770 is a high-performance pneumatic tool that stands out in the industry due to its durability and versatility. It has been engineered for demanding applications in various work environments, including automotive, manufacturing, and construction. This tool is designed to provide efficient, powerful performance while ensuring user comfort and safety.

One of the key features of the 7940-8770 is its lightweight design. Weighted at only a fraction of similar tools in the market, it minimizes fatigue during extended use. Users can enjoy prolonged operation without feeling burdened, which significantly enhances productivity. Additionally, the ergonomic handle allows for a secure grip, ensuring greater control and precision during operations.

The 7940-8770 incorporates advanced technologies, notably its patented air control system. This innovative feature enables users to adjust the air pressure depending on the application, ensuring optimal torque output. With a maximum torque of 600 ft-lbs, the tool is capable of handling heavy-duty tasks with ease. Furthermore, the impact mechanism has been finely tuned to deliver outstanding power while reducing vibration, which also contributes to the tool's user-friendly profile.

Another prominent characteristic of the Ingersoll-Rand 7940-8770 is its robust construction. It is built with high-quality materials that withstand the rigors of daily use, extending its lifespan. The tool’s components are designed to resist wear and tear, even in the most demanding conditions. As a result, maintenance is minimal, making it a cost-effective solution for professionals.

In terms of safety, the 7940-8770 features an integrated exhaust system that directs air away from the user, significantly improving the working environment. This feature is crucial in preventing inhalation of debris, promoting a safer workspace.

In conclusion, the Ingersoll-Rand 7940-8770 is a dependable pneumatic tool that merges power, durability, and user comfort. With its advanced air control system, robust design, and safety features, it is ideally suited for both professional tradespeople and DIY enthusiasts. Whether tackling automotive tasks or industrial applications, the 7940-8770 proves to be a valuable asset in any toolkit. Its competitive edge lies in its ability to deliver consistent performance while ensuring user satisfaction through thoughtful engineering and design.